| Attribute | 1100 Series HPLCAgilent | |
|---|---|---|
| OEM | ABM | Agilent |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | 1995– |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | ABM -407B-1-S-CES293 Robot | Agilent 1100 Series HPLC |
| Cited variants | — |
|
| Specifications | ||
| Model | ABM-407B-1-S-CES293[5] | 1100 Series[6] |
| Description | ROBOT[5] | — |
| Refurbished RTP RTA | AG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[5] | — |
| KLA-Tencor Spare Parts and Service | RS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[5] | — |
| Refurbished Isotropic Plasma Etcher | Matrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[5] | — |
| Refurbished PECVD, ALD Equipment | Cambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[5] | — |
| Refurbished Mask Aligner | Canon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[5] | — |
| Refurbished Bonding | SUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[5] | — |
| Refurbished Wafer Prober | Electroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[5] | — |
| Flow range (isocratic pump) | — | 0.2 ml/min to 10 ml/min[1] |
| Flow range (binary pump) | — | 0.1 – 5.0 ml/min (settable 0.001 – 5 ml/min)[2] |
| Pressure range (binary pump) | — | 0 – 400 bar (0 – 5880 psi)[2] |
| Flow precision (binary pump) | — | < 0.3 % RSD (typically 0.15 %) at 1 ml/min[2] |
| Wavelength range (DAD) | — | 190 – 950 nm[2] |
| Detector short term noise (DAD) | — | ± 1 × 10⁻⁵ AU at 254 and 750 nm[2] |
| Autosampler injection range | — | 0.1 – 100 µl (standard), up to 1500 µl with multiple draw[2] |
| Autosampler precision | — | Typically < 0.5 % RSD from 5 – 100 µl[2] |
| Module weight (isocratic pump, VWD, TCC) | — | 11.0 kg (25.0 lbs) each[3] |
| Module dimensions (width × depth × height, most modules) | — | 345 × 435 × 140 mm (13.5 × 17 × 5.5 in)[3] |
| Line voltage | — | 100 – 120 or 220 – 240 VAC, ± 10 %[3] |
| Ambient operating temperature | — | 0 – 55 °C (32 – 131 °F)[3] |
| Make/OEM | — | Agilent (formerly Hewlett-Packard)[6] |
| Category | — | High Performance Liquid Chromatography (HPLC)[6] |
| Introduction Year | — | 1995[2] |
| Modules/Components | — | Isocratic pump (G1310A), binary pump (G1312A), quaternary pump (G1311A), capillary pump, preparative pump, standard autosampler (G1313A), well-plate autosampler, thermostatted micro autosampler, micro well-plate autosampler, thermostatted column compartment (G1316A), vacuum degasser (G1322A), variable wavelength detector (G1314A/B), diode array detector (G1315A/B), multiwavelength detector, fluorescence detector (G1321A), refractive index detector (G1362A), mass selective detector LC/MSD VL/SL, LC/MSD Trap, controllers, handheld control module, ChemStation software[1] |
| Pump Flow Range (Isocratic) | — | 0.001 – 10 ml/min[1] |
| Pump Flow Range (Binary) | — | 0.001 – 5.0 ml/min[1] |
| Pump Flow Range (Quaternary) | — | 0.001 – 10 ml/min[1] |
| Pump Flow Range (Capillary) | — | 0.01 μl/min – 2.5 ml/min[1] |
| Pump Flow Range (Preparative) | — | 0.001 – 100 ml/min[1] |
| Flow Precision | — | 0.3% RSD (typically < 0.15% RSD)[1] |
| Pressure Range (Binary/Isocratic/Quaternary) | — | 0 – 400 bar (0 – 5880 psi)[2] |
| VWD Wavelength Range | — | 190 – 600 nm[1] |
| DAD/MWD Wavelength Range | — | 190 – 950 nm[1] |
| DAD Short-term Noise | — | ± 1 × 10-5 AU at 254 nm and 750 nm[1] |
| Column Compartment Temperature Range | — | 10 °C below ambient to 80 °C[1] |
| Autosampler Injection Volume (Standard) | — | 0.1 – 100 μl standard range, up to 1800 μl or 5000 μl with extension[1] |
| Detectors | — | Variable Wavelength (VWD), Multiwavelength (MWD), Diode Array (DAD), Fluorescence (FLD), Refractive Index (RID), Mass Selective (LC/MSD VL/SL, LC/MSD Trap)[1] |
| Control and Data Handling | — | Handheld controller, Agilent ChemStation (2D/3D), Cerity Networked Data System, ChemStation Plus, Security Pack for 21 CFR Part 11 compliance[1] |
| Communications | — | Controller-area network (CAN), GPIB, RS-232C, APG Remote (ready, start, stop, shut-down), LAN (optional)[2] |
| Dimensions (Isocratic Pump, VWD, FLD) | — | 345 mm × 435 mm × 140 mm (13.5 × 17 × 5.5 inches) (W × D × H)[3] |
| Weight (Isocratic Pump) | — | 11.0 kg (25.0 lbs)[3] |