Comparison ledger
ABM -407B-1-S-CES293 Robot, Agilent 34970 A Data Acquisition, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 34970 A Data AcquisitionAgilent | |
|---|---|---|
| OEM | ABM | Agilent |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | ABM -407B-1-S-CES293 Robot | Agilent 34970 A Data Acquisition |
| Cited variants | — | |
| Specifications | ||
| Model | ABM-407B-1-S-CES293[2] | — |
| Description | ROBOT[2] | — |
| Refurbished RTP RTA | AG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2] | — |
| KLA-Tencor Spare Parts and Service | RS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2] | — |
| Refurbished Isotropic Plasma Etcher | Matrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2] | — |
| Refurbished PECVD, ALD Equipment | Cambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2] | — |
| Refurbished Mask Aligner | Canon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2] | — |
| Refurbished Bonding | SUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2] | — |
| Refurbished Wafer Prober | Electroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2] | — |
| Resolution | — | 6½ digits (22 bits)[3] |
| Basic dcV accuracy | — | 0.004% basic 1-year dcV accuracy[3] |
| Scan rate | — | up to 250 channels per second[1] |
| Single channel reading rate | — | up to 500 readings per second[1] |
| Maximum channels | — | 60 channels (120 single-ended)[1] |
| Nonvolatile reading memory | — | 50,000 time-stamped readings[1] |
| Module slots | — | 3[1] |
| Standard interfaces | — | GPIB (IEEE-488) and RS-232[1] |
| Internal DMM Resolution | — | 6½ digits (22 bits)[3] |
| Basic DCV Accuracy (1-year, 10V range) | — | 0.004% of reading + 0.0005% of range[3] |
| Maximum Scan Rate | — | 250 channels/second (dcV with 34902A)[3] |
| Maximum Single-Ended Channels | — | 120 (using three 34908A modules)[3] |
| Number of Module Slots | — | 3[1] |
| Reading Memory | — | 50,000 time-stamped readings (non-volatile)[3] |
| Interfaces (34970A) | — | GPIB (IEEE-488) and RS-232[1] |
| Power Consumption | — | 12 W (25 VA peak)[3] |
| Weight | — | 3.6 kg (8.0 lbs)[3] |
| Operating Temperature Range | — | 0°C to 55°C[3] |
| Power Line Frequency | — | 45 Hz to 66 Hz, automatically sensed[3] |
| Basic DC voltage accuracy | — | 0.004% of reading + 0.0005% of range (1-year, 10 V range)[3] |
| Maximum channels per mainframe | — | 60 two-wire channels (120 single-ended)[1] |
| Non-volatile reading memory | — | 50,000 time-stamped readings[1] |
| DC voltage ranges | — | 100 mV, 1 V, 10 V, 100 V, 300 V[3] |
| Resistance ranges | — | 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ[3] |
| Temperature measurement types | — | Thermocouple (types B, E, J, K, N, R, S, T), RTD, thermistor[1] |
| Standard interfaces (34970A) | — | GPIB (IEEE-488) and RS-232[4] |