Waferpedia

Comparison ledger

0020 17484 PartversusSIV 500

Applied Materials 0020 17484 Part, Ulvac SIV 500, side by side. Every value shown is drawn from the cited encyclopedia entries.

Email
Side-by-side comparison of selected equipment models
Attribute
0020 17484 PartApplied Materials
SIV 500Ulvac
OEMApplied MaterialsUlvac
CategoryDepositionDeposition
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0020 17484 PartUlvac SIV 500
Cited variants—
Specifications
ConfigurationBar, Cap Bank, Hdpcvd 300mm Ultima X[2]—
Process module stations—3 (P1, P2, P3)[1]
Pulsed DC power supply power—5 kW[1]
Substrate size capability—up to 1000mm x 1000mm[3]
P3 sputtering power supply frequency—13.56 MHz[1]
Cryo pump size—12 inch[1]
Turbo/water pump size—12 inch[1]
Voltage—208 VAC +/- 5%, 3 phase, 60 Hz, 3 wire plus ground, 145.5 A[3]
Chamber dimensions—500mm x 420mm[1]
Magnetron sources—3[1]
DC planar sources—1[1]
Substrate diameter max—8 inches[1]
Carrier size—500mm x 500mm[3]
Process modules—3-station (P1, P2, P3)[1]
Power supply—5 kW pulsed DC[1]
P3 dedicated to—ITO or other TCF with O₂ MFC and 13.56 MHz RF supply[1]
Chamber size (base machine)—500 mm × 420 mm[1]
Maximum substrate size—1000 mm × 1000 mm[3]
Pallet size (configured)—500 mm × 500 mm[3]
Supported wafer sizes—100 mm, 150 mm, 200 mm, 300 mm[3]
Pumping—Roughing pump, turbomolecular/water pump, Ulvac 12" cryo pump[1]
Sputter sources—Three magnetron sources and one DC planar source on XYZ stage[1]

Plan your fab

Building a Deposition process? Get a complete equipment list.

Open the fab equipment planner →
Sources (3)Every fact above is drawn from these public sources
  1. [1]tarasemi.comtarasemi.com
  2. [2]inventory listing
  3. [3]fabsurplus.comfabsurplus.com