Waferpedia

Comparison ledger

0020 81665 PartversusCFT 75 Chiller

Applied Materials 0020 81665 Part, Neslab CFT 75 Chiller, side by side. Every value shown is drawn from the cited encyclopedia entries.

Email
Side-by-side comparison of selected equipment models
Attribute
0020 81665 PartApplied Materials
OEMApplied MaterialsNeslab
CategoryLab & Support EquipmentLab & Support Equipment
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones—2009 service-business acquisition
Control system——
Generation——
FamilyApplied Materials 0020 81665 PartNeslab CFT 75 Chiller
Cited variants—
  • CFT75 (R134a)[1]
Specifications
ConfigurationGuide, Fiber Mount, Ude, Lk[2]—
Make—Neslab[3]
Model—CFT 75[3]
Type—Recirculating chiller[1]
Refrigeration system—Air-cooled[1]
Phase—Single phase[4]
Temperature range—5C to 35C[4]
Flow rate at 20ºC / 30 PSI (PD2 Pump)—3.8 GPM[4]
Cooling capacity at 20C—2100 Watts[4]
Available voltage—200-230V 1 Ph[4]
Plumbing connections—1/2 inch NPT[1]
Cooling fluid—Tap water is the recommended fluid for operation.[1]
Cooling system—Air-cooled refrigeration system[1]
Cooling capacity—2100 watts at 20°C[4]
Power requirements—208/230V, 60Hz[1]
Reservoir volume—6.8 liters (1.8 gallons)[1]
Refrigerant—R134a[1]
Flow rate at 20°C / 30 PSI (PD1 Pump)—0.9 GPM[4]
Air intake required—800 cubic feet per minute[1]
Temperature stability—±0.5°[1]
Dimensions (H x W x D)—67.3 x 37.8 x 65.4 cm (26½ x 147/8 x 25¾ inches)[1]
Pump capacity—60 PSI / 30 Bar; flow 2.0 LPM (5 PSI) to 20 LPM (15-20 PSI) approx.[1]
Flow Rate at 20ºC / 30 PSI (PD1 Pump)—.9 GPM[4]
Cooling options—Air only[4]
Condenser—Air-cooled; air drawn in the front and discharged through rear and side[1]
Compliance—CE label; LVD 73/23/EEC; UL 3101-1:93; EMC 89/336/EEC EN 55011 Class A[1]
Fluid viscosity requirement—50 centistokes or less at lowest operating temperature[1]
Full rated capacity ambient temperature—Up to approximately +38°C[1]
Air intake requirement—Approximately 800 cubic feet per minute for full rated capacity[1]
OEM—Neslab[3]
Cooling configuration—Air only[4]
Unit dimensions (H x W x D)—67.3 x 37.8 x 65.4 cm[1]
Cooling fluid recommendation—Tap water[1]
Cooling type—Air cooled[1]
Cooling capacity at 20°C—2100 W[4]

Plan your fab

Building a Lab & Support Equipment process? Get a complete equipment list.

Open the fab equipment planner →
Sources (4)Every fact above is drawn from these public sources
  1. [1]chillercity.comchillercity.com
  2. [2]inventory listing
  3. [3]Equipment inventory listing
  4. [4]trilliumus.comtrilliumus.com