0010-13627 High Efficiency RF MatchversusCFT 75 Chiller

Applied Materials 0010-13627 High Efficiency RF Match, Neslab CFT 75 Chiller, side by side. Every value shown is drawn from the cited encyclopedia entries.

Email
Side-by-side comparison of selected equipment models
Attribute
OEMApplied MaterialsNeslab
CategoryLab & Support EquipmentLab & Support Equipment
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones—2009 service-business acquisition
Control system——
Generation——
FamilyApplied Materials 0010-13627 High Efficiency RF MatchNeslab CFT 75 Chiller
Cited variants—
  • CFT75 (R134a)[1]
Specifications
ConfigurationHE, BIAS[2]—
Asset Number70430[3]—
TypeHigh Efficiency RF Match - HE, BIAS[3]Recirculating chiller[1]
OEMApplied Materials[3]Neslab[4]
Model0010-13627[3]CFT 75[4]
Make—Neslab[4]
Refrigeration system—Air-cooled[1]
Phase—Single phase[5]
Temperature range—5C to 35C[5]
Flow rate at 20ºC / 30 PSI (PD2 Pump)—3.8 GPM[5]
Cooling capacity at 20C—2100 Watts[5]
Available voltage—200-230V 1 Ph[5]
Plumbing connections—1/2 inch NPT[1]
Cooling fluid—Tap water is the recommended fluid for operation.[1]
Cooling system—Air-cooled refrigeration system[1]
Cooling capacity—2100 watts at 20°C[5]
Power requirements—208/230V, 60Hz[1]
Reservoir volume—6.8 liters (1.8 gallons)[1]
Refrigerant—R134a[1]
Flow rate at 20°C / 30 PSI (PD1 Pump)—0.9 GPM[5]
Air intake required—800 cubic feet per minute[1]
Temperature stability—±0.5°[1]
Dimensions (H x W x D)—67.3 x 37.8 x 65.4 cm (26½ x 147/8 x 25¾ inches)[1]
Pump capacity—60 PSI / 30 Bar; flow 2.0 LPM (5 PSI) to 20 LPM (15-20 PSI) approx.[1]
Flow Rate at 20ºC / 30 PSI (PD1 Pump)—.9 GPM[5]
Cooling options—Air only[5]
Condenser—Air-cooled; air drawn in the front and discharged through rear and side[1]
Compliance—CE label; LVD 73/23/EEC; UL 3101-1:93; EMC 89/336/EEC EN 55011 Class A[1]
Fluid viscosity requirement—50 centistokes or less at lowest operating temperature[1]
Full rated capacity ambient temperature—Up to approximately +38°C[1]
Air intake requirement—Approximately 800 cubic feet per minute for full rated capacity[1]
Cooling configuration—Air only[5]
Unit dimensions (H x W x D)—67.3 x 37.8 x 65.4 cm[1]
Cooling fluid recommendation—Tap water[1]
Cooling type—Air cooled[1]
Cooling capacity at 20°C—2100 W[5]

Plan your fab

Building a Lab & Support Equipment process? Get a complete equipment list.

Open the fab equipment planner →