Side-by-side comparison of selected equipment models
Attribute
OEMABMTektronix
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-1-S-CES293 RobotTektronix 485 Oscilloscope
Cited variants—
Specifications
ModelABM-407B-1-S-CES293[2]—
DescriptionROBOT[2]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2]—
Frequency—48–440 Hz (50–400 Hz Maximum)[3]
Watts Max—80[3]
Amps Max—0.9 A 115 V[3]
Line Fuse—3 A Fast[3]
Bandwidth (50 Ω)—DC to at least 350 MHz[1]
Bandwidth (1 MΩ)—DC to at least 250 MHz[1]
Risetime (50 Ω)—1 ns[1]
Risetime (1 MΩ)—1.4 ns[1]
Sweep rate range—1 ns/div to 0.5 s/div in 27 calibrated steps[1]
Deflection factor—5 mV/div to 5 V/div in 10 calibrated steps, variable to 12.5 V/div uncalibrated[1]
Input impedance (50 Ω)—50 Ω within 0.5%[1]
Input impedance (1 MΩ)—1 MΩ within 1% paralleled by approximately 20 pF[1]
CRT display area—8 horizontal x 10 vertical divisions (0.8 cm/div)[1]
Accelerating potential—21 kV[1]
Calibrator frequency—Selectable 1 kHz and 1 MHz[1]
Calibrator amplitude—5 V into 1 MΩ load, 0.5 V into 50 Ω load[1]
Line voltage range—115 V (90–136 V) or 230 V (180–272 V); 48–440 Hz[1]
Power consumption—60 W maximum at 115 V, 60 Hz; 0.9 A max[1]
Operating temperature—−15°C to +55°C[1]
Storage temperature—−55°C to +75°C[1]
Dimensions (H x W x D)—6 9/16 in x 12 in (with handle) x 18 1/2 in (with panel cover)[1]
Net weight (without accessories)—21 lb[1]
Net weight (with panel cover and accessories)—24 lb[1]
Sources (3)Every fact above is drawn from these public sources
  1. [1]archive.orgarchive.org
  2. [2]dealer listingsemistarcorp.com
  3. [3]inventory listing