.498 PSL WaferversusMetaPulse 200 Metal Film Measurement

KLA .498 PSL Wafer, Onto Innovation MetaPulse 200 Metal Film Measurement, side by side. Every value shown is drawn from the cited encyclopedia entries.

Email
Side-by-side comparison of selected equipment models
Attribute
OEMKLAOnto Innovation
CategoryMetrology & InspectionMetrology & Inspection
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyKLA .498 PSL WaferOnto Innovation MetaPulse 200
Specifications
ConfigurationNIST Traceable[1]MP200 Double Path Tool Non Copper Tool[2]
NIST traceabilityYes[1]—
OEMKLA[1]—
CategoryMetrology & Inspection[1]—
TraceabilityYes[1]—
DescriptionParticle-sizing calibration standard[1]—
Cooling Water Required Minimum Flow—0.79 GPM (3.00 l/m) Minimum Temperature: 12*C[2]
Maximum Temperature—20*C[2]
Wafer sizes—6 inch, 8 inch[2]
Tool type—MP200 Double Path Tool[2]
Chuck—6 inch chuck[2]
Cooling water minimum flow—0.79 GPM (3.00 l/m)[2]
Cooling water minimum temperature—12*C[2]
Cooling water maximum temperature—20*C[2]
Operating air pressure—14.00 PSI (96,534.20 N/sq m)[2]
Vacuum required—0.98 in Hg (24.89 mm Hg)[2]
Vintage—2006[2]
Wafer diameter—200 mm[3]
Year of manufacture—1998[3]
Process—Wafer inspection[3]
Configuration description—Pattern Recognition; 200 mm ergonomic cassette-tilt loaders; Pulse Wafer Transport System; 200 mm chuck; 200 mm wafer probe; 200 mm linear positioning stage; Ultrafast 800 nm laser; Programmable motion controller; Color printer (cleanroom approved); 266 MHz Pentium II Motherboard; 2 GB hard drive; CD ROM drive; LCD screen; Keyboard and Trackball; GEM compliant SECS-II[3]
Measurement capability—Can simultaneously measure the individual thicknesses of up to six layers in a multi-layer metal film stack[4]
Throughput—Up to 60 wafers per hour[4]
Measurement spot—10 µm[4]
Measurement technique—Picosecond ultrasonic laser sonar (PULSE Technology), non-contact, non-destructive measurement based on laser-induced ultrasound[4]
Make—ONTO / Rudolph[2]
Model—MetaPulse 200[2]
Layer measurement—Up to six layers in a multi-layer metal film stack[4]
Measurement accuracy—Angstrom accuracy[4]
Repeatability—Sub-Angstrom repeatability[4]
Measurement method—Non-contact, non-destructive[4]
Cooling water requirement—Minimum flow 0.79 GPM (3.00 l/m); minimum temperature 12°C; maximum temperature 20°C[2]
Vacuum requirement—0.98 in Hg (24.89 mm Hg)[2]

Plan your fab

Building a Metrology & Inspection process? Get a complete equipment list.

Open the fab equipment planner →