Waferpedia

Agilent

1100 HPLC

Produced 1995–Agilent 1100 HPLC family
Research Quality: 50% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Agilent 1100 HPLC is a modular high-performance liquid chromatography system. The Agilent 1100 HPLC was introduced in 1995. The Agilent 1100 HPLC can be controlled with a handheld controller, Agilent ChemStation, or LAN-based control.[1][2]

1100 HPLC — Inventory photo
Fig. 011100 HPLCInventory photo[3]

Produced

1995–

Vacuum

0.001 to 5 mL/min setpoints[2]

Optics

190 to 950 nm[2]

What it is

The Agilent 1100 HPLC is a high-performance liquid chromatography system used for analytical separations in laboratory work. The Agilent 1100 platform is a modular instrument family built around interchangeable pumps, samplers, column compartments, and detectors.[4][2][5]

The Agilent 1100 series supports liquid chromatography workflows that separate compounds in a sample before detection and data analysis. The Agilent 1100 system can be operated through Agilent ChemStation, OpenLAB CDS, Clarity software, or a handheld controller.[2][5][4]

How it works

The Agilent 1100 HPLC works by driving mobile phase through a column, introducing the sample with an autosampler, and measuring analytes as they elute from the separation column. The modular architecture allows the pump, sampler, column compartment, and detector to be combined for a specific method.[4][5]

The Agilent 1100 series includes isocratic, binary, and quaternary pump options. The Agilent 1100 series also includes variable-wavelength, diode-array, fluorescence, refractive-index, evaporative light-scattering, and mass-selective detector options.[4][2]

The Agilent 1100 series uses a Peltier-based thermostatted column compartment for temperature control. The Agilent 1100 series also includes diagnostic functions intended to support troubleshooting and method operation.[4][2]

Where it fits in the process flow

The Agilent 1100 HPLC sits in analytical laboratory workflows after sample preparation and before result review or reporting. The Agilent 1100 system injects prepared samples, separates their components on the column, and passes the resulting signal to the data system.[5][4]

The Agilent 1100 platform is used for routine quality control, method development, and regulatory laboratory work. The Agilent 1100 series is intended to support automated sequences, data handling, and chromatographic traceability.[2][5]

Applications

The Agilent 1100 HPLC is used for pharmaceutical quality control, impurity analysis, dissolution testing, environmental testing, food and beverage analysis, cannabis potency analysis, natural products analysis, clinical screening, forensic screening, and chemical or materials purity work.[1]

What do the numbers mean?

Vacuum & pumping3

Pump configurations
Isocratic, binary, quaternary, capillary, and preparative pumps[2]
Accurate?
Binary pump flow range
0.001 to 5 mL/min setpoints[2]
Accurate?
Binary pump pressure range
0 to 400 bar[2]
Accurate?

Optics & imaging4

Detector types
Variable, multiwavelength, diode-array, mass selective, refractive index, and fluorescence detectors[2]
Accurate?
Thermostatted column compartment
Peltier-based design with ambient, subambient, and above-ambient operation[2]
Accurate?
Diode-array detector wavelength range
190 to 950 nm[2]
Accurate?
Diode-array detector diodes
1024 diodes[2]
Accurate?

Control & software1

Control options
Handheld controller, Agilent ChemStation, or LAN-based control[2]
Accurate?

Configuration & options2

Platform
Modular HPLC system[1]
Accurate?
Introduction year
1995[1]
Accurate?

Vintage & configurations

  1. 1995Production start[1]

    Agilent introduced the 1100 Series in 1995.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Pump configurationsIsocratic, binary, quaternary, capillary, and preparative pumps[2]
  • Binary pump flow range0.001 to 5 mL/min setpoints[2]
  • Binary pump pressure range0 to 400 bar[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What modules can be combined in the Agilent 1100 system?

The Agilent 1100 system can combine pumps, detectors, samplers, and column compartments in different modular configurations.[2][4]

What pump configurations are available on the Agilent 1100 series?

The Agilent 1100 series includes isocratic, binary, and quaternary pump configurations.[4][2]

What software can operate the Agilent 1100 system?

The Agilent 1100 system can be operated with Agilent ChemStation, OpenLAB CDS, Clarity software, or a handheld controller.[2][5][4]

Not publicly documented

The following facts about the 1100 HPLC are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the 1100 HPLC are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 1100 HPLC are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 1100 HPLC are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 1100 HPLC is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 1100 HPLC are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (6)Every fact above is drawn from these public sources
  1. [1]gentechscientific.com — gentechscientific.comgentechscientific.com
  2. [2]cdn.labwrench.com — cdn.labwrench.comcdn.labwrench.com
  3. [3]Inventory photo
  4. [4]Agilent 1100 HPLC System | 1-Year Warranty! — gmi-inc.comgmi-inc.com
  5. [5]https://manuals.plus/asin/B01J930G20.pdf — manuals.plusmanuals.plus
  6. [6]Equipment inventory listing
Was this page accurate?

Last updated Oct 13, 2026.

Compare with similar tools