Perkin Elmer

Lambda 750 Spectrophotometer

Lambda 750 Spectrophotometer — Inventory photo
Fig. 01Lambda 750 SpectrophotometerInventory photo[1]
  • Plate 01Perkin Elmer Lambda 750 Spectrophotometer #61116

    Bid ServicellcWatch on YouTube

Power

90 VAC - 250 VAC, 50/60 Hz; 400 VA[2]

Performance

± 0.0012 A[2]

Optics

190 nm - 3300 nm[2]

What it is

The Perkin Elmer Lambda 750 is a double-beam, double-monochromator, ratio-recording UV/Vis/NIR spectrophotometer.[2]

How it works

General reference — not yet source-verified

In a double-beam spectrophotometer, light from a source is split into two paths: one passes through the sample and the other through a reference, allowing real-time compensation for fluctuations in source intensity.

Where it fits in the process flow

General reference — not yet source-verified

Spectrophotometers are used in quality control and research laboratories for analyzing the optical properties of materials, such as transmittance, reflectance, and absorbance. In precision optics, they characterize filters, coatings, and other optical components.

Applications

General reference — not yet source-verified

UV/Vis/NIR spectrophotometry is applied across chemistry, biochemistry, and materials science for quantitative analysis and characterization.

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • No guarantee on performance

What do the numbers mean?

Power & electrical2

Beam Splitting System
Chopper (46+ Hz, Cycle: Dark/Sample/Dark/Reference, Chopper Segment Signal Correction CSSC).[2]
Accurate?
Power Requirements
90 VAC - 250 VAC, 50/60 Hz; 400 VA[2]
Accurate?

Optics & imaging15

Optical System
All reflecting optical system (SiO2 coated) with holographic grating monochromator with 1440 Lines/mm UV/Vis blazed at 240 nm and 360 Lines/mm NIR blazed at 1100 nm, Littrow mounting, sample thickness compensated detector optics.[2]
Accurate?
Detector
Photomultiplier R955 for high energy in the whole UV/Vis wavelength range; Peltier cooled PbS detector for NIR.[2]
Accurate?
Wavelength Range
190 nm - 3300 nm[2]
Accurate?
UV/Vis Resolution
≤ 0.17 nm[2]
Accurate?
NIR Resolution
≤ 0.20 nm[2]
Accurate?
Stray Light (at 200 nm, 12 g/L KCl USP/DAP method)
> 2 A ≤ 0.0001 %T[2]
Accurate?
Stray Light (at 220 nm, 10 g/L NaI ASTM method)
≤ 0.0001 %T[2]
Accurate?
Wavelength Accuracy
± 0.15 nm UV/Vis; ± 0.5 nm NIR[2]
Accurate?
Wavelength Reproducibility (UV/Vis, Deuterium Lamp Lines)
≤ 0.1 nm[2]
Accurate?
Wavelength Reproducibility (NIR, Deuterium Lamp Lines)
≤ 0.06 nm[2]
Accurate?
Photometric Linearity (at 3.0 A, addition of filters UV/Vis at 546.1 nm, 2 nm Slit, 1-sec integration)
± 0.020 A[2]
Accurate?
Bandpass
0.17 nm - 5.00 nm in 0.01 nm increments UV/Vis range; 0.20 nm - 20.00 nm in 0.04 nm increments NIR range[2]
Accurate?
Photometric Stability (after warm-up at 500 nm, 0 A, 2 nm Slit, 2-sec integration, Peak to Peak)
≤ 0.0002 A/h[2]
Accurate?
Baseline Flatness (190 nm - 3100 nm, slit UV/Vis 2 nm, slit NIR Servo Mode)
± 0.0015 A[2]
Accurate?
Photometric Noise RMS (0 A and 500 nm)
≤ 0.00005 A[2]
Accurate?

Performance1

Photometric Accuracy (Double Aperture Method 1 A)
± 0.0012 A[2]
Accurate?

Control & software2

Operating System
Win7 Professional N[1]
Accurate?
Principle
Double beam, double monochromator, ratio recording UV/Vis/NIR spectrophotometer with microcomputer electronics, controlled by a DELL PC or compatible personal computer.[2]
Accurate?

Dimensions & facilities3

Instrument Dimensions (W x D x H)
1020 mm x 740 mm x 300 mm[2]
Accurate?
Instrument Weight
~ 77 kg[2]
Accurate?
Light Beam (above base plate)
90 mm; 120 mm beam separation; 3 mm - 12 mm beam height[2]
Accurate?

Configuration & options15

UV-VIS + NIR[1]
Accurate?
Accessories Included:[1]
Accurate?
150mm Integration Sphere[1]
Accurate?
ARTA (Absolute Reflectance Transmittance Accessory)[1]
Accurate?
2 Standard Sample Holders on Pedestal[1]
Accurate?
2 Sample Holders[1]
Accurate?
1 Variable Angle Transmittance Sample Holder[1]
Accurate?
1 High Reflection[1]
Accurate?
Source
Pre-aligned tungsten-halogen and deuterium.[2]
Accurate?
Photometric Range
6 A (using reference-beam attenuation)[2]
Accurate?
Primary Sample Compartment (W x D x H)
200 mm x 300 mm x 220 mm[2]
Accurate?
Secondary Sample Compartment (W x D x H)
480 mm x 300 mm x 220 mm[2]
Accurate?
Digital I/O
RS 232 C[2]
Accurate?
Temperature Range
10 °C - 35 °C[2]
Accurate?
Recommended Humidity
10 - 70% relative humidity, non-condensing[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
Lambda 750SThe Lambda 750S has a reduced wavelength range of 200 nm to 2500 nm compared to the Lambda 750's 190 nm to 3300 nm.nanoqam.ca[3]
Interested in this tool?
Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Beam Splitting SystemChopper (46+ Hz, Cycle: Dark/Sample/Dark/Reference, Chopper Segment Signal Correction CSSC).[2]
  • Power Requirements90 VAC - 250 VAC, 50/60 Hz; 400 VA[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Frequently asked questions

What is the wavelength range of the Lambda 750?

The wavelength range is 190 nm to 3300 nm.[2]

What are the UV/Vis and NIR resolutions?

UV/Vis resolution is ≤ 0.17 nm; NIR resolution is ≤ 0.20 nm.[2]

What detectors are used in the instrument?

A photomultiplier tube (R955) is used for UV/Vis detection and a Peltier-cooled PbS detector is used for NIR detection.[2]

What software controls the Lambda 750?

The instrument is controlled by PerkinElmer's UV WinLab software.[3]

Not publicly documented

The following facts about the Lambda 750 Spectrophotometer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Lambda 750 Spectrophotometer are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the Lambda 750 Spectrophotometer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the Lambda 750 Spectrophotometer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Lambda 750 Spectrophotometer are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the Lambda 750 Spectrophotometer are on record.

    Answerable by: university cleanroom staff or an OEM application specialist