Waferpedia

Comparison ledger

Twinscan XT 1400 FversusNSR S 203 B

ASML Twinscan XT 1400 F, Nikon NSR S 203 B, side by side. Every value shown is drawn from the cited encyclopedia entries.

Documented as functional equivalents— Same function class: Lithography, null[1]
Side-by-side comparison of selected equipment models
Attribute
OEMASMLNikon
CategoryLithographyLithography
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyASML Twinscan XT 1400Nikon NSR S 203
Specifications
Configuration193nm (ArF)[1]248 nm[5]
MakeASML[1]—
ModelTwinscan XT 1400 F[1]NSR S 203 B[4]
CategoryLithography[2]—
Wafer Sizes12 inch[1]—
Wavelength193 nm[1]248 nm[5]
Process Module200 mm[2]—
Conversion Kit300 mm[2]—
Resolution65 nm[3]—
Numerical Aperture0.65 to 0.93[3]—
Throughput133 wph (@125 exp per wafer)[3]—
Software Version—MCSV[4]
CIM—SECS[4]
Handler System—WL Type 3[4]
Factory Interface—Open Cassette[4]
Excluded—Hard Drives (2)[4]
Process—Scanner[5]
Handler—WL Type 3[7]
IU Flare—0.84%[7]
Lens Flare—8.50%[7]
Uniformity—6.00%[7]
Power—541 mW/cm2[7]
Total Focus Deviation—0.202 µm[7]
Astigmatism—0.119 µm[7]
Coma—0.040 µm[7]
ISO DOF—0.275 µm[7]
Wafer size—200 mm (8 inch)[4]
Process type—Scanner[5]
CIM interface—SECS[4]
Iso DOF—0.241 µm[8]
Light source—Cymer ELS 5410[6]
Manufacturer—Nikon[4]

Plan your fab

Building a Lithography process? Get a complete equipment list.

Open the fab equipment planner →
Sources (8)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]waferpedia.comwaferpedia.com
  3. [3]smartsystem.cnsmartsystem.cn
  4. [4]inventory listing
  5. [5]inventory listing
  6. [6]inventory listing
  7. [7]inventory listing
  8. [8]inventory listing