Comparison ledger
Edwards XDS 10 Dry Scroll, Edwards XDS 35 i, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | XDS 10 Dry ScrollEdwards | XDS 35 iEdwards |
|---|---|---|
| OEM | Edwards | Edwards |
| Category | — | Lab & Support Equipment |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Edwards XDS | Edwards XDS |
| Cited variants | — | |
| Specifications | ||
| Voltage | 200-230 V[2] | — |
| Frequency | 50/60 Hz[2] | — |
| Current | 2.0-2.1 A[2] | — |
| OEM | Edwards[2] | — |
| Model | XDS 10[2] | XDS 35 i[5] |
| Equipment name | XDS 10 Dry Scroll Pump[2] | — |
| Make | Edwards[2] | — |
| Type | Dry Scroll Pump[2] | dry scroll vacuum pump[1] |
| Inlet flange | NW 25[3] | — |
| Exhaust flange | NW 25[3] | — |
| Ultimate vacuum | 6 x 10^-2 mbar[3] | 0.01 mbar (0.008 Torr)[1] |
| Rotational speed | 1800 rpm[3] | — |
| Weight | 24 kg / 54 lbs[3] | 48 kg (105 lb)[1] |
| Peak pumping speed | 6.5 cfm[4] | 35 m3/h (21 cfm)[1] |
| Motor | 1 phase[4] | — |
| Operating temperature range | 10 to 40 °C[4] | 5 to 40 C (41 to 104 F)[1] |
| Configuration | — | 1750 rpm[5] |
| Power | — | 520W (0.7hp)[5] |
| Nominal rotation speed | — | 1750 rpm[1] |
| Motor power | — | 520 W[1] |
| Power at ultimate | — | 440 W[1] |
| Supply voltage | — | 100-120/200-240 V (+/- 10%)[1] |
| Supply frequency | — | 50/60 Hz[1] |
| Inlet connection | — | NW40[1] |
| Exhaust connection | — | NW25[1] |
| Noise level at ultimate | — | 57 dB(A)[1] |
| Product form | — | oil-free dry scroll vacuum pump[7] |
| Equipment type | — | Pump[5] |
| Pump type | — | Dry scroll pump[1] |
| Gas ballast water vapour handling capacity | — | 240 gh-1[1] |