7890 B 7000 C GC-MS-MS

Precision OpticsAgilent 7890 family
Research Quality: 50% complete
Email

The Agilent 7890 B / 7000 C GC-MS-MS is a gas chromatography-tandem mass spectrometry system. The Agilent 7890 B / 7000 C GC-MS-MS includes a 7693 Autosampler. The Agilent 7890 B / 7000 C GC-MS-MS includes an EI XTR Source.[1][2]

7890 B 7000 C GC-MS-MS — Inventory photo
Fig. 017890 B 7000 C GC-MS-MSInventory photo[1]

What it is

The Agilent 7890 B / 7000 C GC-MS-MS is a gas chromatography-tandem mass spectrometry system.[2]

How it works

The Agilent 7890 B / 7000 C GC-MS-MS includes an inlet, an autosampler, an ion source, and vacuum pumping support as part of its analytical chain.[1][2]

Where it fits in the process flow

General reference — not yet source-verified

A gas chromatography-tandem mass spectrometry system is used in analytical workflows for separating and identifying compounds after sample preparation.

The Agilent 7890 B / 7000 C GC-MS-MS sits in the measurement stage of an analytical sequence rather than in a fabrication step.

Applications

General reference — not yet source-verified

Gas chromatography-tandem mass spectrometry is used for compound analysis in laboratories that need separation and mass-based identification.

What do the numbers mean?

Vacuum & pumping3

Rough Pump[1]
Accurate?
Pump
Rough Pump[2]
Accurate?
Vacuum & pumping
Rough Pump[2]
Accurate?

Gas & chemistry1

Tool type
Gas chromatography-tandem mass spectrometry system[2]
Accurate?

Configuration & options11

with[1]
Accurate?
7693 Autosampler[1]
Accurate?
Mixed Mode Inlet (MMI Inlet)[1]
Accurate?
EI XTR Source[1]
Accurate?
7693 Injector and Tray[1]
Accurate?
Manufacturer
Agilent[2]
Accurate?
Model
7890 B / 7000 C[2]
Accurate?
Autosampler
7693 Autosampler[2]
Accurate?
Inlet
Mixed Mode Inlet (MMI Inlet)[2]
Accurate?
Source
EI XTR Source[2]
Accurate?
Injector and tray
7693 Injector and Tray[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationRough Pump[1]
  • Tool typeGas chromatography-tandem mass spectrometry system[2]
  • PumpRough Pump[2]
  • Vacuum & pumpingRough Pump[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of system is the Agilent 7890 B / 7000 C GC-MS-MS?

The Agilent 7890 B / 7000 C GC-MS-MS is a gas chromatography-tandem mass spectrometry system.[2]

What does the system include in its analytical chain?

The Agilent 7890 B / 7000 C GC-MS-MS includes an inlet, an autosampler, an ion source, and vacuum pumping support as part of its analytical chain.[2]

Where does the system sit in the process flow?

The Agilent 7890 B / 7000 C GC-MS-MS sits in the measurement stage of an analytical sequence rather than in a fabrication step.[2]

Not publicly documented

The following facts about the 7890 B 7000 C GC-MS-MS are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 7890 B 7000 C GC-MS-MS are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 7890 B 7000 C GC-MS-MS are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 7890 B 7000 C GC-MS-MS are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 7890 B 7000 C GC-MS-MS are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 7890 B 7000 C GC-MS-MS is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]waferpedia.com — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 13, 2026.

Compare with similar tools

View all →