Waferpedia

Onto Innovation

Accent / Bio-Rad QS 2200 A Automated FT-IR

Accent / Bio-Rad QS 2200 A Automated FT-IR — Inventory photo
Fig. 01Accent / Bio-Rad QS 2200 A Automated FT-IRInventory photo[1]

Wafer size

Dual cassette wafer handling

Power

120V, 1Ph., 10A, 50/60 Hz[1]

What is it?

What do the numbers mean?

Power & electrical1

Voltage
120V, 1Ph., 10A, 50/60 Hz[1]
Accurate?

Wafer handling4

Wafer size
Dual cassette wafer handling[1]
Accurate?
Wafer size
Dual Cassette Wafer Handling for 100mm – 200mm Wafers.[1]
Accurate?
GENMARK 3 Axis Robot with Integrated Flat Finder & Controller[1]
Accurate?
Accent Robot Interface[1]
Accurate?

Control & software3

Accent 013-4738-2 Stage Controller[1]
Accurate?
Accent GUI Application Software[1]
Accurate?
SECS/GEM Interface Software[1]
Accurate?

Configuration & options8

Si epi, SiN[1]
Accurate?
Film Z thickness measurement[1]
Accurate?
Potassium Bromide (KBr) Beamsplitter[1]
Accurate?
Accent 013-4758-2 AC Power Box[1]
Accurate?
Windows XP[1]
Accurate?
19” Color Flatscreen Monitor[1]
Accurate?
Configured for reflective measurements only[1]
Accurate?
Refurbished[1]
Accurate?
Interested in this tool?
Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage120V, 1Ph., 10A, 50/60 Hz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Not publicly documented

The following facts about the Accent / Bio-Rad QS 2200 A Automated FT-IR are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Accent / Bio-Rad QS 2200 A Automated FT-IR are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Accent / Bio-Rad QS 2200 A Automated FT-IR are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Accent / Bio-Rad QS 2200 A Automated FT-IR are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Accent / Bio-Rad QS 2200 A Automated FT-IR are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Accent / Bio-Rad QS 2200 A Automated FT-IR is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]Inventory photo
Was this page accurate?

Last updated Jul 29, 2026.

Compare with similar tools

View all →