Waferpedia

Agilent

3585 A Spectrum Analyzer

Agilent 35xx family
Research Quality: 50% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Agilent 3585A Spectrum Analyzer is a spectrum analyzer. The Agilent 3585A Spectrum Analyzer has a 20 Hz to 40 MHz frequency range. The Agilent 3585A Spectrum Analyzer includes HP-IB interface support.[1][2][3]

3585 A Spectrum Analyzer — Inventory photo
Fig. 013585 A Spectrum AnalyzerInventory photo[1]

Power

20Hz-40MHz[1]

Performance

± 0.4 dB[3]

What it is

The Agilent 3585A Spectrum Analyzer is a spectrum analyzer used for frequency-domain measurement of electrical signals.[1][4]

How it works

The Agilent 3585A supports manual entry, stepped entry, and continuous entry of frequency and amplitude settings, and it provides marker functions for readout on the display.[3][4]

Where it fits in the process flow

The Agilent 3585A is used for signal analysis, frequency-response measurement, and distortion-related measurements on electronic systems and components.[3]

Applications

The Agilent 3585A is used for baseband signal analysis, noise and distortion analysis, and frequency-response measurements.[3]

The Agilent 3585A is applied to crystals, filters, amplifiers, and communication-related signals.[3]

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • Screen fails to stay illuminated

What do the numbers mean?

Power & electrical5

Frequency
20Hz-40MHz[1]
Accurate?
Frequency range
20 Hz to 40 MHz[2]2 sources
Accurate?
Resolution
0.1 Hz[3]
Accurate?
Resolution bandwidth
3 Hz[3]
Accurate?
Built-in tracking generator
Yes[3]
Accurate?

Optics & imaging1

Unit powers on but screen fails to stay illuminated[1]
Accurate?

Performance1

Amplitude accuracy
± 0.4 dB[3]
Accurate?

Control & software1

Interface
HP-IB interface[3]
Accurate?

Configuration & options7

Unit being sold As-is[1]
Accurate?
Input impedance
50 Ohm, 75 Ohm, and 1 Mohm selectable input impedance[3]
Accurate?
Display
1001 x 1024 digital storage display[3]
Accurate?
Model
3585 A[1]
Accurate?
Selectable input impedance
50 Ohm, 75 Ohm, and 1 Mohm[3]
Accurate?
Measurement range
-137 dBm to +30 dBm[3]
Accurate?
Dynamic range
80 dB[3]
Accurate?

Vintage & configurations

  1. 1979-09Manual printed[4]

    The operating and service manual was printed in September 1979.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Frequency20Hz-40MHz[1]
  • Frequency range20 Hz to 40 MHz[2]
  • Resolution0.1 Hz[3]
  • Resolution bandwidth3 Hz[3]
  • Built-in tracking generatorYes[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What analyzer architecture does the Agilent 3585 A use?

The Agilent 3585 A is a swept heterodyne, triple-conversion circuit with a fully synthesized, phase-continuous local oscillator.[3]

Does the Agilent 3585 A include a tracking generator?

The Agilent 3585 A includes a built-in tracking generator.[3]

What kinds of measurements is the Agilent 3585 A used for?

The Agilent 3585 A is used for spurious, harmonic, and intermodulation product measurements, as well as noise and distortion analysis and frequency-response checks.[3]

Not publicly documented

The following facts about the 3585 A Spectrum Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the 3585 A Spectrum Analyzer are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 3585 A Spectrum Analyzer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the 3585 A Spectrum Analyzer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 3585 A Spectrum Analyzer are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the 3585 A Spectrum Analyzer are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]manualsplus.com — manualsplus.commanualsplus.com
  3. [3]testequipmentdepot.com — testequipmentdepot.comtestequipmentdepot.com
  4. [4]ia801406.us.archive.org — ia801406.us.archive.orgia801406.us.archive.org
Was this page accurate?

Last updated Oct 13, 2026.

Compare with similar tools