Test & ProbeLogitech LG2 family
Research Quality: 60% complete
Email

The Logitech LG2 Autocollimator is a highly accurate angle measuring device used in the production of parallel specimens. The LG2 achieves a typical setting accuracy of better than 2 arc seconds and has an adjustment range of ±25 minutes of arc with an aperture of 30mm.[1][2]

LG2 — web.archive.org
Fig. 01LG2web.archive.org[1]

Power

90-260V 50/60Hz[1]

Performance

Better than 2 arc seconds[1]

Optics

Lamda/8[1]

What it is

The Logitech LG2 is an autocollimator in the test and measurement category. The Logitech LG2 is a highly accurate angle measuring device used in the production of parallel specimens. The Logitech LG2 is intended for measuring small angles, internal and external angular measurement of porro prisms, and testing for wedge difference. The Logitech LG2 is suitable for use with a wide range of sample types and holding fixtures, and is particularly suitable for use with Logitech PP5 series polishing jigs. The Logitech LG2 has a typical setting accuracy better than 2 arc seconds, a 30 mm aperture, optical reference flatness of Lambda/8, an adjustment range of ±25 minutes of arc, and a 90-260 V, 50-60 Hz power supply.[1][2]

How it works

The Logitech LG2 focuses light through a dark field graticule. The Logitech LG2 passes the beam through X and Y axes optical datum adjustment plates and reflects the beam by a mirror through the objective lens onto the upper surface of the specimen being examined. The Logitech LG2 then reflects the image onto another mirror, which projects it through a light field graticule into the eyepiece. The Logitech LG2 uses this optical path to set the specimen surface in relation to the plane of an optical reference surface and to measure angular deviation.[2]

The Logitech LG2 is set up by first placing the X and Y axes adjustment controls at their mid-range positions. The Logitech LG2 then uses three optical datum adjustment screws on the base of the stand to bring the image into alignment with the field of view. The Logitech LG2 uses the X and Y axes adjustment to bring the bright and dark field graticules into exact coincidence as viewed through the eyepiece. The Logitech LG2 may be used with alternative specimen holders by retaining the optical reference standard as the base plate and placing specimens or specimen holders on the reference standard or on three accurate support balls positioned across its surface.[2]

Where it fits in the process flow

The Logitech LG2 is used in the production of parallel specimens. The Logitech LG2 enables parallel faces to be prepared by bringing the polished face of the specimen into alignment with the plane of the optical reference standard and then polishing the second face in this plane. The Logitech LG2 can prepare specimens to parallelism better than 2 seconds of arc using this method. The Logitech LG2 can also generate angles of up to ±3 minutes of arc by placing an angled slip gauge on top of the optical reference standard and resetting the autocollimator.[2][1]

Applications

General reference — not yet source-verified

Autocollimators in this class are used in precision optics and specimen preparation where angular control, parallelism, or deliberate wedge must be established on polished parts. Such instruments are relevant to laboratory and process environments that prepare optical components, technical materials, and other specimens requiring controlled surface orientation. The measurement task commonly supports prism work, flat sample preparation, and angular setup for subsequent finishing or inspection.

  • Production of parallel specimens
  • Measuring small angles
  • Internal and external angular measurement of porro prisms
  • Testing for wedge difference

What do the numbers mean?

Power & electrical1

Power supply
90-260V 50/60Hz[1]
Accurate?

Optics & imaging3

Optical reference flatness
Lamda/8[1]
Accurate?
Optical Reference Flatness
Lambda/8[1]
Accurate?
Standard kit
Autocollimator body; cast iron base and support stand; power pack; spare pack bulb; optical reference stand; operations manual[2]
Accurate?

Performance1

Typical setting accuracy
Better than 2 arc seconds[1]
Accurate?

Configuration & options4

Aperture
30mm[1]
Accurate?
Adjustment range
±25 minutes of arc[1]
Accurate?
Type
Autocollimator[1]
Accurate?
Use
Angle measuring device used in the production of parallel specimens[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power supply90-260V 50/60Hz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the typical setting accuracy of the LG2 Autocollimator?

The typical setting accuracy is better than 2 arc seconds.[1][2]

What is the aperture of the LG2 Autocollimator?

The aperture is 30 mm.[1][2]

What is the adjustment range of the LG2 Autocollimator?

The adjustment range is ±25 minutes of arc.[1][2]

What power supply is required for the LG2 Autocollimator?

The power supply requirement is 90–260 V, 50/60 Hz.[1][2]

Can the LG2 Autocollimator be used to generate angled specimens?

Yes, angled specimens can be prepared by placing an angled slip gauge on top of the optical reference standard and resetting the autocollimator using the standard technique, which offsets the polishing plane by the desired angle. Angles of up to ±3 minutes of arc can be generated with this method.[2]

Not publicly documented

The following facts about the LG2 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the LG2 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the LG2 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the LG2 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the LG2 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the LG2 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]web.archive.org — web.archive.orgweb.archive.org
  2. [2]logitech.uk.com — logitech.uk.comlogitech.uk.com
Was this page accurate?

Last updated Oct 20, 2026.

Compare with similar tools

View all →