Waferpedia

Nikon

Labophot 2

Metrology & InspectionNikon Labophot 2 family
Research Quality: 30% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Nikon Labophot 2 is a modular microscope utilizing the Nikon CF optical system. The Labophot 2 is available with either a forward or rear facing quintuple nosepiece and features a 6-volt, 20-watt Köhler illumination system with a halogen lamp and variable control.[1]

Nikon logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Power

6V-30W halogen bulb (Philips special type)[3]

Optics

Nikon CF optical system[1]

How it works

The Nikon Labophot 2 is available with either a forward-facing or rear-facing quintuple nosepiece. The Nikon Labophot 2 has a Köhler illumination system consisting of a halogen lamp and a variable illuminator control potentiometer. The Nikon Labophot 2 has a substage condenser mount that allows the condenser to be changed quickly without re-adjusting the centering screws. The Nikon Labophot 2 is available with binocular and trinocular eyepiece tubes that feature a thirty-degree inclination and Seidentoph design. The Nikon Labophot 2 also supports a quick-change filter holder for mounting up to two filter blocks. The Nikon Labophot 2 platform supports accessories for phase contrast, fluorescence, polarizing microscopy, and microphotography.[1]

What do the numbers mean?

Power & electrical8

Illumination
6V-20W halogen lamp with Köhler illumination and variable control potentiometer[1]
Accurate?
Lamp (alternative)
6V-30W halogen bulb (Philips special type)[3]
Accurate?
Illumination Type
6V-30W halogen bulb (special Philips type); Köhler illumination[3]
Accurate?
Lamp Power
6V, 20W (standard) or 6V-30W (replacement bulb)[1]
Accurate?
Lamp house
100 watt mercury lamphouse[5]
Accurate?
Power supply
100 watt mercury power supply[5]
Accurate?
Lamphouse
100 watt mercury lamphouse[5]
Accurate?
Illumination system
6-volt, 20-watt Köhler illumination system with halogen lamp and variable illuminator control potentiometer[1]
Accurate?

Wafer handling1

Filter Holder
Quick-change filter holder (ND filter cassette, filter receptacle)[3]
Accurate?

Optics & imaging16

Optical System
Nikon CF optical system[1]
Accurate?
Objectives (standard)
E Plan 4/0.1 160/-, E Plan 10/0.25 LWD, E Plan 40/0.65 160/0.17 in a quintuple nosepiece[1]
Accurate?
Objectives (standard configuration)
E Plan 4/0.1 160/-, E Plan 10/0.25 LWD, E Plan 40/0.65 160/0.17[1]
Accurate?
Objective Magnifications Available
4X, 10X, 20X, 40X, 50X, 100X[4]
Accurate?
Objectives
Five objective lenses: 100X, 50X, 40X, 10X, and 4X[4]
Accurate?
Illumination
Light source with filters and a collimator[4]
Accurate?
Head
Trinocular head with C-mount camera coupler[5]
Accurate?
Fluorescence illuminator
Fluorescence vertical illuminator[5]
Accurate?
Objectives
Plan 4X phase contrast objective[5]
Accurate?
Objectives
Plan 10X phase contrast objective[5]
Accurate?
Objectives
Plan 20X phase contrast objective[5]
Accurate?
Objectives
40X phase contrast objective[5]
Accurate?
Objectives
Fluor 40X brightfield objective with correction collar[5]
Accurate?
Objectives
100X, 50X, 40X, 10X, and 4X objective lenses[4]
Accurate?
Illuminator
Fluorescence vertical illuminator[5]
Accurate?
Objectives
Plan 4X phase contrast, Plan 10X phase contrast, Plan 20X phase contrast, 40X phase contrast, and Fluor 40X brightfield objective with correction collar[5]
Accurate?

Performance1

Stage
High-precision stage; mechanical rectangular or circular rotatable stage with six minute vernier gradations[1]
Accurate?

Configuration & options32

Polarizing[2]
Accurate?
Focusing (coarse)
12mm per rotation[3]
Accurate?
Focusing (fine)
0.1mm per rotation, each graduation 1 micron[3]
Accurate?
Eyepieces (standard)
Two CFWN 10x/20[1]
Accurate?
Stage (standard)
Mechanical slide stage[1]
Accurate?
Condenser (standard)
Abbe 1.25 brightfield condenser[1]
Accurate?
Eyepiece tube inclination
30 degrees (Seidentoph design)[1]
Accurate?
Phase Contrast
Can use Green interference filter (GIF) for phase difference microscopy[3]
Accurate?
Nosepiece
Quintuple nosepiece; forward or rear facing[1]
Accurate?
Eyepieces (Oculars)
CFWN 10x/20 eyepieces (standard); 10X widefield adjustable eyepieces[1]
Accurate?
Stage
Mechanical rectangular or circular rotatable with six minute vernier gradations; graded adjustable stage[1]
Accurate?
Focusing Movement
Coarse focus knob moves stage 12mm per rotation; fine focus knob moves stage 0.1mm per rotation (1 micron per graduation)[3]
Accurate?
Condenser Centering
Centering screws provided; quick-change condenser mount without re-adjusting centering screws[1]
Accurate?
Make
Nikon[2]
Accurate?
Model
Labophot 2[2]
Accurate?
Microscope type
Polarizing microscope[2]
Accurate?
Microscope type
Binocular microscope[4]
Accurate?
Ocular lenses
10X ocular lenses[4]
Accurate?
Stage
Graded, adjustable stage[4]
Accurate?
Microscope type
Fluorescence and phase contrast trinocular microscope[5]
Accurate?
Eyepieces
10X widefield adjustable eyepieces[5]
Accurate?
Phase contrast condenser
Turret style phase contrast condenser with phase 1, 2, 3, darkfield, and brightfield stops[5]
Accurate?
Manufacturer
Nikon[2]
Accurate?
Binocular microscope[4]
Accurate?
Trinocular microscope[5]
Accurate?
Eyepieces
10X ocular lenses[4]
Accurate?
Filter cubes
UV (DAPI) cube and blue cube[5]
Accurate?
Condenser
Turret-style phase contrast condenser with phase 1, 2, 3, darkfield, and brightfield stops[5]
Accurate?
Nosepiece
Forward or rear facing quintuple nosepiece[1]
Accurate?
Eyepiece tube
Binocular and trinocular eyepiece tubes with 30-degree inclination and Seidentoph design[1]
Accurate?
Filter holder
Quick-change filter holder for up to two filter blocks[1]
Accurate?
Applications
Clinical, biological, industrial, and educational laboratories[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Illumination6V-20W halogen lamp with Köhler illumination and variable control potentiometer[1]
  • Lamp (alternative)6V-30W halogen bulb (Philips special type)[3]
  • Illumination Type6V-30W halogen bulb (special Philips type); Köhler illumination[3]
  • Lamp Power6V, 20W (standard) or 6V-30W (replacement bulb)[1]
  • Lamp house100 watt mercury lamphouse[5]
  • Power supply100 watt mercury power supply[5]
  • Lamphouse100 watt mercury lamphouse[5]
  • Illumination system6-volt, 20-watt Köhler illumination system with halogen lamp and variable illuminator control potentiometer[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What optical system does the Nikon Labophot 2 use?

The Nikon Labophot 2 utilizes the Nikon CF optical system.[1]

Not publicly documented

The following facts about the Labophot 2 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Labophot 2 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Labophot 2 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Labophot 2 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Labophot 2 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Labophot 2 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]labwrench.com — labwrench.comlabwrench.com
  2. [2]inventory listing
  3. [3]manualslib.com — manualslib.commanualslib.com
  4. [4]medicalinst.com — medicalinst.commedicalinst.com
  5. [5]spachoptics.com — spachoptics.comspachoptics.com
Was this page accurate?

Last updated Oct 17, 2026.

Compare with similar tools