Waferpedia

Agilent

8508 A Vector Voltmeter

Agilent 85xx family
Research Quality: 40% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

8508 A Vector Voltmeter — Inventory photo
Fig. 018508 A Vector VoltmeterInventory photo[1]

Power

RF voltage and phase measurements[2]

Optics

Up to 0.1° over the full ±180° range[2]

How it works

The HP 8508A vector voltmeter is a fully automatic tuned receiver for RF voltage and phase measurements. The HP 8508A uses a narrowband measuring technique. The HP 8508A has dynamic range over 90 dB and sensitivity of 10 μV. The HP 8508A measures the phase difference between two input channels with at least 0.1 degree resolution over a full +180 degree to -180 degree range. The HP 8508A can be used for measurements such as electrical length, phase distortion, or impedance. The standard unit is supplied with the HP 85081B input module, which has two high-impedance probe inputs operating from 100 kHz to 1 GHz. Option 050 is supplied with the HP 85082A input module, whose 50 Ω inputs operate from 300 kHz to 2 GHz. The HP 8508A has an HPIB interface.[3][2]

Applications

The HP 8508A is used for RF voltage and phase measurements. The HP 8508A can measure electrical length, phase distortion, and impedance. The HP 8508A can use any CW source as a stimulus, including a source that is part of the device being tested, so measurements can be made under normal operating conditions. The HP 8508A can store a reference and use it in later measurements, which allows individual circuit sections to be characterized and adjusted independently.[3][2]

What do the numbers mean?

Power & electrical4

Function
RF voltage and phase measurements[2]
Accurate?
Frequency range with HP 85081A input module
100 kHz to 1 GHz[2]
Accurate?
Frequency range with HP 85082A input module
300 kHz to 2 GHz[2]
Accurate?
Maximum input voltage
2 V peak AC or ±50 VDC[2]
Accurate?

Optics & imaging1

Phase resolution
Up to 0.1° over the full ±180° range[2]
Accurate?

Control & software1

Interface
HPIB[2]
Accurate?

Configuration & options5

Option 050[1]
Accurate?
Instrument type
Vector voltmeter[1]
Accurate?
Dynamic range
Over 90 dB[2]
Accurate?
Sensitivity
10 µV[2]
Accurate?
Option 050[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
8508A Vector Voltmeter Option 050——Option 050 is listed with the instrument.Equipment inventory listing[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • FunctionRF voltage and phase measurements[2]
  • Frequency range with HP 85081A input module100 kHz to 1 GHz[2]
  • Frequency range with HP 85082A input module300 kHz to 2 GHz[2]
  • Maximum input voltage2 V peak AC or ±50 VDC[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the Agilent 8508A?

The Agilent 8508A is a vector voltmeter.[4][1]

What does Option 050 indicate on the 8508A?

Option 050 is supplied with the HP 85082A input module, which has 50 Ω inputs operating from 300 kHz to 2 GHz.[3][1]

What input module comes with the standard 8508A?

The standard HP 8508A is supplied with the HP 85081B input module, which has two high-impedance probe inputs operating from 100 kHz to 1 GHz.[3]

Not publicly documented

The following facts about the 8508 A Vector Voltmeter are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 8508 A Vector Voltmeter are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 8508 A Vector Voltmeter are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 8508 A Vector Voltmeter are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 8508 A Vector Voltmeter is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 8508 A Vector Voltmeter are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]rosenkranz-elektronik.com — rosenkranz-elektronik.comrosenkranz-elektronik.com
  3. [3]https://www.testequipmenthq.com/datasheets/Agilent-8508A-Datasheet.pdf — testequipmenthq.comtestequipmenthq.com
  4. [4]8508 A Vector Voltmeter — Agilent | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
  5. [5]8508A Vector Voltmeter Operating and Service Manual | Keysight — keysight.comkeysight.com