Waferpedia

Branson

Omni 2000 Aqueous Ultrasonic

Branson Omni 2000 Aqueous Ultrasonic family
Research Quality: 40% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Branson Omni 2000 Aqueous Ultrasonic is an aqueous ultrasonic system. The Branson Omni 2000 Aqueous Ultrasonic is a fully-configured ultrasonic cleaning and rinsing system with a built-in dryer. The Branson Omni 2000 Aqueous Ultrasonic includes two heated rinse tanks in a cascade arrangement.[1]

Omni 2000 Aqueous Ultrasonic — Inventory photo
Fig. 01Omni 2000 Aqueous UltrasonicInventory photo[2]

How it works

The Omni 2000 accomplishes precision cleaning in the first chamber. The first chamber is equipped with Branson Series 7000 industrial 40 kHz ultrasonic components and thermostatically controlled heat. The Omni 2000 has a recirculating pump and filter system for continuous particulate removal. The Omni 2000 includes two heated rinse tanks in a cascade arrangement. Rinse water overflows from the third tank into the second tank in a counter-flow arrangement. The second rinse tank includes ultrasonic components as standard. The drying station uses elevated temperature and rapid air movement to dry parts. The controls are mounted in a control box and operate at 24 volts.[1]

What do the numbers mean?

Power & electrical3

Cleaning ultrasonic components
Branson Series 7000 industrial 40 kHz ultrasonic components[1]
Accurate?
Ultrasonic output
1000 watts/tanks[1]
Accurate?
Input voltage
208-240V AC, 35 amps, 3 phase[1]
Accurate?

Wafer handling1

With two dimentional robots[2]
Accurate?

Configuration & options5

Make
Branson[2]
Accurate?
Model
Omni 2000[2]
Accurate?
Type
Aqueous ultrasonic system[3]
Accurate?
Fully-configured ultrasonic cleaning and rinsing system with a built-in dryer[1]
Accurate?
Working tank size
16" x 20" x 16" D[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Cleaning ultrasonic componentsBranson Series 7000 industrial 40 kHz ultrasonic components[1]
  • Ultrasonic output1000 watts/tanks[1]
  • Input voltage208-240V AC, 35 amps, 3 phase[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

How is the Omni 2000 arranged?

The Omni 2000 has a cleaning chamber, two heated rinse tanks in a cascade arrangement, and a drying station. Rinse water overflows from the third tank into the second tank in a counter-flow arrangement.[1]

What ultrasonic hardware is used in the cleaning chamber?

The first chamber is equipped with Branson Series 7000 industrial 40 kHz ultrasonic components. The second rinse tank also includes ultrasonic components as standard.[1]

Does the Omni 2000 include filtration and recirculation?

The Omni 2000 has a recirculating pump and filter system to continuously remove particulate material.[1]

Not publicly documented

The following facts about the Omni 2000 Aqueous Ultrasonic are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Omni 2000 Aqueous Ultrasonic are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Omni 2000 Aqueous Ultrasonic are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Omni 2000 Aqueous Ultrasonic are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Omni 2000 Aqueous Ultrasonic are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Omni 2000 Aqueous Ultrasonic is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]branson.emerson.com — branson.emerson.combranson.emerson.com
  2. [2]Inventory photo
  3. [3]waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 17, 2026.

Compare with similar tools

View all →