The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption is a 100% forced convection reflow oven. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption has 14 independent temperature controlled 350°C semi-circular balanced flow lead free heating zones. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption includes a complete computer control system with Windows Home Edition software.[1][2]

1707 MK 5 Ultra Low Power & Nitrogen Consumption — Inventory photo
Fig. 011707 MK 5 Ultra Low Power & Nitrogen ConsumptionInventory photo[1]

What it is

General reference — not yet source-verified

Reflow ovens heat assemblies on a continuous conveyor to drive a controlled thermal profile through preheat, soak, reflow, and cooling. Reflow ovens are used after solder paste deposition and component placement to form solder joints across an assembled substrate.

How it works

The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption uses semi-circular balanced flow heater modules and 100% forced convection. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption has 14 independent temperature controlled 350°C semi-circular balanced flow lead-free heating zones. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption has a 73 inch heated tunnel length and 1 internal cooling module with 15 inches of cooling. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption has 18 inch on-load and 18 inch off-load conveyor sections. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption uses a spike zone design for minimal liquidous time.[1][2]

Where it fits in the process flow

General reference — not yet source-verified

Reflow ovens are placed in the assembly flow after solder paste printing and component placement. Reflow ovens are followed by inspection, test, and any downstream cleaning or finishing steps required by the manufacturing route.

Applications

The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption is intended for reflow processing with lead-free thermal profiles. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption combines conveyorized heating, internal cooling, and profiling software for controlled solder reflow processing.[1][2]

What do the numbers mean?

Power & electrical2

Power
400V, 60 HZ, 3 phase, 100 AMPS per phase[1]
Accurate?
Voltage
400V, 60 HZ, 3 phase, 100 AMPS per phase · Left to Right Conveyor Travel[1]
Accurate?

Performance2

Profile Storage/Overlay Software including the following features:[1]
Accurate?
Profile graph overlay of "benchmark" profile with current profile[1]
Accurate?

Control & software8

Complete Computer Control System including:[1]
Accurate?
Complete Software Package including:[1]
Accurate?
Windows based Computer, Windows Home Edition Software, Password Protection[1]
Accurate?
Complete KIC & ECD Profiling & Storage Software including the following features:[1]
Accurate?
Temperature
PID temperature control to ensure zone temperature stability to +/- 1°C[1]
Accurate?
Temperature control
PID temperature control to ensure zone temperature stability to +/- 1°C[1]
Accurate?
Computer control
Complete computer control system[1]
Accurate?
Software
Windows based computer, Windows Home Edition software, password protection[1]
Accurate?

Dimensions & facilities1

Floor space requirements
142"L x 59"W x 63"H[1]
Accurate?

Configuration & options24

With Semi-circular balanced flow heater modules[1]
Accurate?
100% forced convection reflow oven[1]
Accurate?
18” On Load Conveyor and 18” Off Load Conveyor[1]
Accurate?
73" Heated Tunnel Length · 1 Internal Cooling Module with 15” of Cooling[1]
Accurate?
Temperature
14 Independent Temperature Controlled 350°C Semi-Circular Balanced Flow “Lead Free” Heating Zones[1]
Accurate?
Spike Zone Design for minimal liquidous time[1]
Accurate?
Flat Panel Color Monitor, Keyboard & Mouse support[1]
Accurate?
ECD CPK & SPC data and alarm logging with timed download or printout capability[1]
Accurate?
5 Thermocouple "Real Time" profiling[1]
Accurate?
Profile Graph Storage of up to 500 graphs[1]
Accurate?
Profile graph phase shifting to align two graphs[1]
Accurate?
Moveable slope window providing average slope over given portion of graph[1]
Accurate?
6 color graphics to distinguish between graphs[1]
Accurate?
Process type
100% forced convection reflow oven[1]
Accurate?
Heating zones
14 independent temperature controlled 350°C semi-circular balanced flow "lead free" heating zones[1]
Accurate?
Heater modules
Semi-circular balanced flow heater modules[1]
Accurate?
Conveyor
18" on load conveyor and 18" off load conveyor[1]
Accurate?
Heated tunnel length
73"[1]
Accurate?
Cooling
1 internal cooling module with 15" of cooling[1]
Accurate?
Profiling
5 thermocouple "real time" profiling[1]
Accurate?
Profile storage
Profile graph storage of up to 500 graphs[1]
Accurate?
Alarm logging
ECD CPK & SPC data and alarm logging with timed download or printout capability[1]
Accurate?
Motion direction
Left to right conveyor travel[1]
Accurate?
Belt
22" wide 42-36-18 heavy weave 400°C high temperature mesh belt[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power400V, 60 HZ, 3 phase, 100 AMPS per phase[1]
  • Voltage400V, 60 HZ, 3 phase, 100 AMPS per phase · Left to Right Conveyor Travel[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of machine is the Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption?

The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption is a 100% forced convection reflow oven with multiple heating zones, conveyor transport, cooling, and computer control.[2]

How many heating zones does the Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption have?

The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption has 14 independent temperature controlled 350°C semi-circular balanced flow lead-free heating zones.[1][2]

What control and profiling features are included on the Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption?

The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption includes a complete computer control system, a flat panel color monitor with keyboard and mouse support, Windows based computer control with Windows Home Edition software and password protection, ECD CPK and SPC data and alarm logging, and complete KIC and ECD profiling and storage software. The Heller 1707 MK 5 Ultra Low Power & Nitrogen Consumption supports 5 thermocouple real-time profiling, profile storage of up to 500 graphs, benchmark profile overlay, phase shifting, a moveable slope window, and 6 color graphics.[1][2]

Not publicly documented

The following facts about the 1707 MK 5 Ultra Low Power & Nitrogen Consumption are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 1707 MK 5 Ultra Low Power & Nitrogen Consumption are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 1707 MK 5 Ultra Low Power & Nitrogen Consumption are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 1707 MK 5 Ultra Low Power & Nitrogen Consumption are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 1707 MK 5 Ultra Low Power & Nitrogen Consumption are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 1707 MK 5 Ultra Low Power & Nitrogen Consumption is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]1707 MK 5 Ultra Low Power & Nitrogen Consumption — Heller | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 16, 2026.

Compare with similar tools

View all →