The Keysight 33120 A Waveform is a function/arbitrary waveform generator. The Keysight 33120 A Waveform is specified for 15 MHz operation. The Keysight 33120 A Waveform has built-in arbitrary waveform capability.[1][2][3][4][5]

Keysight33120 A Waveform
No photo available yet

Power

15 MHz[1]

Optics

12 bits[4]

What it is

The Keysight 33120A is a function and arbitrary waveform generator.[2][4][5]

How it works

The 33120A uses direct digital synthesis to create stable output signals.[4][5]

The 33120A provides standard sine, square, triangle, ramp, noise, and other waveforms, and it includes arbitrary waveform capability with 12-bit resolution and a 40 MSa/s sampling rate.[2][4][5]

The 33120A includes internal AM, FM, FSK, burst, and sweep functions for modulation and signal variation.[2][4][5]

Where it fits in the process flow

The 33120A also fits in automated test setups because it supports GPIB and RS-232 interfaces and SCPI programmability.[2][4][5]

Applications

The 33120A is used for general-purpose electronic signal generation, including sine, square, triangle, ramp, noise, and arbitrary waveforms.[2][4][5]

The 33120A supports tasks such as waveform creation, modulation testing, swept-frequency testing, and phase-related signal generation when fitted with the phase-lock and TCXO option.[2][4][5]

What do the numbers mean?

Power & electrical3

15 MHz[1]
Accurate?
Type
Function/arbitrary waveform generator[2]
Accurate?
Maximum frequency
15 MHz[2]
Accurate?

Optics & imaging1

Amplitude resolution
12 bits[4]
Accurate?

Control & software1

Standard interfaces
GPIB (IEEE-488) and RS-232[2]
Accurate?

Configuration & options3

Arbitrary waveform capability
Built-in[2]
Accurate?
Sample rate
40 MSa/s[4]
Accurate?
Modulation features
AM, FM, FSK, burst, and sweep[4]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Configuration15 MHz[1]
  • TypeFunction/arbitrary waveform generator[2]
  • Maximum frequency15 MHz[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of instrument is the 33120A?

The 33120A is a function and arbitrary waveform generator.[2][4][5]

What is the highest frequency specified for the 33120A?

The 33120A is specified for sine and square wave output to 15 MHz.[2][4][5]

What arbitrary waveform memory does the 33120A provide?

The 33120A provides four downloadable 16,000-point arbitrary waveform memories.[2][4][5]

What remote interfaces does the 33120A support?

The 33120A includes GPIB and RS-232 interfaces as standard.[2][4][5]

What modulation functions are built into the 33120A?

The 33120A includes AM, FM, FSK, burst, and sweep functions.[2][4][5]

Not publicly documented

The following facts about the 33120 A Waveform are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 33120 A Waveform are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 33120 A Waveform are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 33120 A Waveform are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 33120 A Waveform are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 33120 A Waveform is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]eeshop.unl.edu — eeshop.unl.edueeshop.unl.edu
  3. [3]33120 A Waveform — Keysight | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
  4. [4]trsrentelco.com — trsrentelco.comtrsrentelco.com
  5. [5]https://accusrc.com/uploads/datasheets/4724_33120a.pdf — accusrc.comaccusrc.com
Was this page accurate?

Last updated Oct 12, 2026.

Compare with similar tools

View all →