The Tektronix DPO 73304 SX Oscilloscope is a DPO70000SX Series oscilloscope. The Tektronix DPO 73304 SX Oscilloscope provides 2 channels at 33 GHz or 4 channels at 23 GHz. The Tektronix DPO 73304 SX Oscilloscope provides 100 GS/s on 2 channels or 50 GS/s on 4 channels.[1]

Tektronix logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Power

62.5 mV FS to 6 V FS[1]

Optics

10 ps (100 GS/s)[1]

What it is

The Tektronix DPO 73304 SX Oscilloscope is a digital real-time oscilloscope.[2][1]

The DPO 73304 SX belongs to the Tektronix DPO70000SX series.[1]

How it works

The DPO 73304 SX uses real-time acquisition with 33 GHz analog bandwidth and up to 100 GS/s sample rate.[2][1]

The DPO70000SX architecture uses UltraSync multi-unit time synchronization and supports compact standalone operation with external display, keyboard, and mouse.[1]

Where it fits in the process flow

The DPO 73304 SX provides acquisition performance similar to the DPO73304DX bench model in a compact instrument form factor.[1]

Applications

The DPO70000SX series is used for high-speed serial signaling, optical modulation analysis, jitter analysis, noise analysis, and wideband RF signal analysis.[1]

The DPO70000SX series is also used for long-haul coherent optical systems and 400G datacom applications.[1]

What do the numbers mean?

Power & electrical5

Sensitivity Range
62.5 mV FS to 6 V FS[1]
Accurate?
Input coupling
TekConnect channels: DC, 50 ohms to a programmable termination voltage, or ground; ATI channel: DC, 50 Ω[1]
Accurate?
Maximum input voltage
TekConnect channels: up to ±8 V depending on settings; ATI channel: ±0.75 Vpk; Aux channel: ±5.0 Vpk[1]
Accurate?
Bandwidth limit
70 GHz to 1 GHz in 1 GHz steps, or 500 MHz; 5 GHz steps above 35 GHz[1]
Accurate?
Displayed average noise level
≤ -145 dBm/Hz to ≤ -150 dBm/Hz depending on frequency range[1]
Accurate?

Optics & imaging2

Timing Resolution
10 ps (100 GS/s)[1]
Accurate?
Vertical Resolution
8 bits (11 bits with averaging)[3]2 sources
Accurate?

Control & software1

Operating System
Microsoft Windows 7 Ultimate 64-bit[1]
Accurate?

Configuration & options25

Analog Bandwidth
33 GHz[2]
Accurate?
Sample Rate
Up to 100 GS/s[2]
Accurate?
Analog Bandwidth (2 ch mode)
33 GHz[1]
Accurate?
Analog Bandwidth (4 ch mode)
23 GHz[1]
Accurate?
Sample Rate (2 ch mode)
100 GS/s[1]
Accurate?
Sample Rate (4 ch mode)
50 GS/s[1]
Accurate?
Rise Time (typical, 10%-90%)
13 ps[1]
Accurate?
Record Length (standard, per channel)
62.5 M points[1]
Accurate?
Vertical Noise (typical, % of full scale)
0.71% of full scale[1]
Accurate?
Input Coupling
DC, 50 ohms[1]
Accurate?
CPU
Intel Core i7-4970S, 3.9 GHz, quad core[1]
Accurate?
System Memory
32 GB[1]
Accurate?
Display
6.5 in. liquid-crystal active-matrix color display[3]
Accurate?
Series
DPO70000SX Series[1]
Accurate?
Analog channels / bandwidth
2 ch / 33 GHz; 4 ch / 23 GHz[1]
Accurate?
Sample rate per channel
100 GS/s on 2 channels; 50 GS/s on 4 channels[1]
Accurate?
Record length, standard
62.5 M points per channel[1]
Accurate?
Record length, option 10XL
125 M points per channel[1]
Accurate?
Record length, option 20XL
250 M points per channel[1]
Accurate?
Record length, option 50XL
1 G on 2 channels; 500 M on 4 channels[1]
Accurate?
Input resistance
50 Ω ±3% to ±4.4% depending on conditions[1]
Accurate?
Sensitivity range
TekConnect channels: 62.5 mVFS to 6 VFS; ATI channel: 100 mVFS to 300 mVFS[1]
Accurate?
Channel isolation
TekConnect channels in an ATI unit: 60 dB; TekConnect to ATI channel: 55 dB to 27 dB depending on frequency; ATI channel to TekConnect channels: 55 dB to 60 dB depending on frequency[1]
Accurate?
Trigger performance
>25 GHz edge trigger performance; <40 ps glitch trigger performance[1]
Accurate?
Auxiliary trigger input bandwidth
>10 GHz[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Sensitivity Range62.5 mV FS to 6 V FS[1]
  • Input couplingTekConnect channels: DC, 50 ohms to a programmable termination voltage, or ground; ATI channel: DC, 50 Ω[1]
  • Maximum input voltageTekConnect channels: up to ±8 V depending on settings; ATI channel: ±0.75 Vpk; Aux channel: ±5.0 Vpk[1]
  • Bandwidth limit70 GHz to 1 GHz in 1 GHz steps, or 500 MHz; 5 GHz steps above 35 GHz[1]
  • Displayed average noise level≤ -145 dBm/Hz to ≤ -150 dBm/Hz depending on frequency range[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What analog bandwidth is specified for the Tektronix DPO 73304 SX?

The Tektronix DPO 73304 SX has 33 GHz analog bandwidth.[2]

What sample rate is specified for the Tektronix DPO 73304 SX?

The Tektronix DPO 73304 SX has a sample rate of up to 100 GS/s.[2]

How many acquisition channels and what performance modes are given for the DPO 73304 SX?

The DPO 73304 SX provides two channels at 33 GHz and 100 GS/s acquisition or four channels at 23 GHz and 50 GS/s real time acquisition performance.[1]

What acquisition architecture does the DPO70000SX Series use?

The DPO70000SX Series uses patented Asynchronous Time Interleaving architecture for real time signal acquisition.[1]

Not publicly documented

The following facts about the DPO 73304 SX Oscilloscope are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the DPO 73304 SX Oscilloscope are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the DPO 73304 SX Oscilloscope are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the DPO 73304 SX Oscilloscope are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the DPO 73304 SX Oscilloscope are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the DPO 73304 SX Oscilloscope is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]trsrentelco.com — trsrentelco.comtrsrentelco.com
  2. [2]inventory listing
  3. [3]finaltest.netfinaltest.net
Was this page accurate?

Last updated Oct 16, 2026.

Compare with similar tools

View all →