Waferpedia

Tektronix

DTG 5334 Data Timing Generator Mainframe

The Tektronix DTG 5334 is a data timing generator mainframe that combines the features of a data generator, pulse generator, and DC source. The DTG 5334 offers a maximum data rate of 3.35 Gb/s in NRZ mode. The DTG 5334 uses a modular architecture with four slots for plug-in output modules.[1]

DTG 5334 Data Timing Generator Mainframe — Inventory photo
Fig. 01DTG 5334 Data Timing Generator MainframeInventory photo[2]

Power

50 kHz to 3.35 GHz (settable to 3.4 GHz)[1]

Performance

±1 ppm[1]

Optics

0.2 ps[1]

How it works

The DTG 5334 uses a modular architecture: the mainframe provides slots for cold-swappable plug-in output modules, and the instrument can be configured with various combinations of modules to suit different test needs. The mainframe contains a built-in computer running the Windows 2000 operating system, offering a graphical user interface and support for network integration.[1][3]

The DTG 5334 offers a delay resolution of 0.2 ps and can generate data rates from 50 Kb/s to 3.35 Gb/s in NRZ mode. The instrument provides precise control over signal timing, including adjustable delay, phase, and pulse width.[1]

Applications

Additional application areas include magnetic and optical storage device testing, data converter device characterization, and imaging sensor device design and functional test. The instrument can generate stressed eye patterns and inject external jitter for jitter tolerance testing.[1]

What do the numbers mean?

Power & electrical2

Clock Out Frequency Range
50 kHz to 3.35 GHz (settable to 3.4 GHz)[1]
Accurate?
Power Supply
100 to 240 VAC, 47 to 63 Hz[1]
Accurate?

Optics & imaging1

Delay Resolution
0.2 ps[1]
Accurate?

Performance1

Internal Clock Accuracy
±1 ppm[1]
Accurate?

Dimensions & facilities3

Maximum Pattern Depth per Channel
64,000,000 bits[1]
Accurate?
Dimensions (Width x Height x Depth)
445 mm x 266 mm x 462 mm[1]
Accurate?
Weight
17.0 kg[1]
Accurate?

Configuration & options11

Add on:[2]
Accurate?
Tektronix DTGM 30 Module[2]
Accurate?
Tektronix DTGM 32 Module[2]
Accurate?
Clock[2]
Accurate?
Data Rate Range (NRZ)
50 Kb/s to 3.35 Gb/s (settable to 3.4 Gb/s)[1]
Accurate?
Number of Output Module Slots
4[1]
Accurate?
Master-Slave Configuration
Up to two DTG5334 mainframes can be connected[1]
Accurate?
Output Patterns
NRZ, RZ, R1, Pulse (Slots A-D) / NRZ only (Slots E-H)[1]
Accurate?
Random Jitter (Clock Pattern)
<3 psRMS at 3.35 Gb/s with DTGM30, 0.8 Vp-p, delay 0.0 ns[1]
Accurate?
Power Consumption
560 W[1]
Accurate?
Operating Temperature Range
+10 °C to +40 °C[1]
Accurate?
Interested in this tool?
Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Clock Out Frequency Range50 kHz to 3.35 GHz (settable to 3.4 GHz)[1]
  • Power Supply100 to 240 VAC, 47 to 63 Hz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Not publicly documented

The following facts about the DTG 5334 Data Timing Generator Mainframe are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the DTG 5334 Data Timing Generator Mainframe are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the DTG 5334 Data Timing Generator Mainframe are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the DTG 5334 Data Timing Generator Mainframe are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the DTG 5334 Data Timing Generator Mainframe are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the DTG 5334 Data Timing Generator Mainframe is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]download.tek.comdownload.tek.comdownload.tek.com
  2. [2]Inventory photo
  3. [3]https://download.tek.com/manual/071160802web.pdfdownload.tek.comdownload.tek.com
Was this page accurate?

Last updated Aug 14, 2026.

Compare with similar tools

View all →