The Tektronix TDS 5104 B Oscilloscope is a digital phosphor oscilloscope. The Tektronix TDS 5104 B Oscilloscope has 4 input channels and 1 GHz analog bandwidth. The Tektronix TDS 5104 B Oscilloscope supports up to 5 GS/s real-time sample rate.[1]

Tektronix logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

How it works

The TDS5104B is a digital phosphor oscilloscope. The TDS5000B DPO models display, store, and analyze complex signals in real time using amplitude, time, and distribution of amplitude over time. The TDS5000B DPO models use Tektronix DPX acquisition technology and deliver greater than 100,000 waveforms per second capture rates. The TDS5000B models include a complete parametric measurement system with 53 automatic measurements. The TDS5000B models also provide advanced triggers, waveform cursors, waveform math, communication mask testing, and pass fail limit testing.[1][3]

Applications

The TDS5104B is positioned for digital design and debug, mask testing for telecomm, datacomm, and video standards, investigation of transient phenomena, power measurements, video design and debug, spectral analysis, automotive electronics, manufacturing test, electromechanical work, biomedical work, and industrial control.[1][3]

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • Broken screen

What do the numbers mean?

Configuration & options12

Broken Screen[2]
Accurate?
Manufacturer
Tektronix[2]
Accurate?
Model
TDS 5104 B[2]
Accurate?
Instrument type
Digital Phosphor Oscilloscope[1]
Accurate?
Input channels
4[1]
Accurate?
Analog bandwidth (-3 dB)
1 GHz[1]
Accurate?
Real-time sample rate
Up to 5 GS/s[1]
Accurate?
Maximum record length
Up to 16 M record length[1]
Accurate?
Maximum waveform capture rate
100,000 wfms/s[1]
Accurate?
Display
10.4 in. bright color display[1]
Accurate?
Touch screen
Standard on TDS5104B[1]
Accurate?
Automatic measurements
53[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
TDS5034B——350 MHz bandwidth model.download.tek.com[1]
TDS5054B——500 MHz bandwidth model.download.tek.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What kind of instrument is the Tektronix TDS 5104 B?

The Tektronix TDS 5104 B is an oscilloscope and part of the TDS5000B Digital Phosphor Oscilloscope family.[1][4]

How many channels does the TDS5104B have?

The TDS5104B has 4 channels.[1][3]

What bandwidth is specified for the TDS5104B?

The TDS5104B is the 1 GHz model in the TDS5000B family.[1][3]

What sample rate and record length are specified for the TDS5104B family?

The TDS5000B family provides up to 5 GS/s sample rate and up to 16 M record length.[1][3]

Does the TDS5104B include a touchscreen?

The TDS5104B has a standard touch screen.[1][3]

Not publicly documented

The following facts about the TDS 5104 B Oscilloscope are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the TDS 5104 B Oscilloscope are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the TDS 5104 B Oscilloscope are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the TDS 5104 B Oscilloscope is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the TDS 5104 B Oscilloscope are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the TDS 5104 B Oscilloscope are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]download.tek.com — download.tek.comdownload.tek.com
  2. [2]inventory listing
  3. [3]https://www.testequipmenthq.com/datasheets/TEKTRONIX-TDS5104B-Datasheet.pdf — testequipmenthq.comtestequipmenthq.com
  4. [4]TDS 5104 B Oscilloscope — Tektronix | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 15, 2026.

Compare with similar tools

View all →