Waferpedia

Zeiss

1550

Metrology & InspectionZeiss 15xx family
Research Quality: 30% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

Zeiss logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Power

30 kV[1]

Vacuum

High-vacuum 1.0nm at 20kV; 2.5nm at 1kV[4]

Optics

2-5 nm size range[2]

What it is

General reference — not yet source-verified

Scanning electron microscopes are metrology and inspection instruments that form images by scanning a focused electron beam across a sample and collecting emitted signals. Scanning electron microscopes are used when optical microscopy does not provide enough surface detail or material contrast for the inspection task. In semiconductor and microfabrication work, scanning electron microscopes are commonly used to examine patterned features, sidewall shape, defects, particles, and other small surface structures.

How it works

General reference — not yet source-verified

A field emission scanning electron microscope focuses electrons into a very fine probe and rasters that probe over the sample surface. Secondary electron and backscattered electron signals carry different kinds of contrast, so the instrument can emphasize topography, material contrast, or surface detail depending on the detector and operating conditions. Analytical attachments on machines of this class can add elemental and crystallographic information to the image-based inspection workflow.

Where it fits in the process flow

General reference — not yet source-verified

In semiconductor and microfabrication flows, a scanning electron microscope is typically used after a structure has been created or modified and needs visual or dimensional verification. A scanning electron microscope commonly follows lithography, etch, deposition, cleaning, or sample preparation steps when engineers need close inspection of the resulting surface or feature shape. A scanning electron microscope can also be used during failure analysis and process development to compare physical results with intended pattern geometry.

What do the numbers mean?

Power & electrical4

Voltage
30 kV[1]
Accurate?
Operating voltage
30 kV[1]
Accurate?
Accelerating voltage
0.1 - 30 kV[3]
Accurate?
Accelerating voltage
100V to 30kV[4]
Accurate?

Vacuum & pumping1

Spatial resolution
High-vacuum 1.0nm at 20kV; 2.5nm at 1kV[4]
Accurate?

Optics & imaging4

Resolution
2-5 nm size range[2]
Accurate?
Resolution
1 nm[3]
Accurate?
Detectors
Everhart-Thornley, InLens, energy-selected backscattered electrons (ESB)[3]
Accurate?
Detectors
1 × In-lens secondary electron (SED), 1 × Everhart-Thornley secondary electron (SED), 1 × Robinson-type back-scatter electron (BSED)[4]
Accurate?

Configuration & options2

Equipment type
Scanning Electron Microscope (SEM)[1]
Accurate?
SEM source type
Schottky field-emission[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
LEO 1550———chemie.uni-hamburg.de[3]
LEO (Zeiss) 1550 Field Emission SEM———nnci.net[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage30 kV[1]
  • Operating voltage30 kV[1]
  • Accelerating voltage0.1 - 30 kV[3]
  • Accelerating voltage100V to 30kV[4]
  • Spatial resolutionHigh-vacuum 1.0nm at 20kV; 2.5nm at 1kV[4]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of instrument is the Zeiss 1550?

It is a scanning electron microscope (SEM).[1]

Not publicly documented

The following facts about the 1550 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 1550 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 1550 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 1550 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 1550 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 1550 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]nnci.net — nnci.netnnci.net
  3. [3]chemie.uni-hamburg.de — chemie.uni-hamburg.dechemie.uni-hamburg.de
  4. [4]serc.carleton.eduserc.carleton.edu