Waferpedia

Nikon

NSR-2205i11D

Lithography0.35 micronProduced 1995–Nikon NSR-2205i11D family
Research Quality: 50% complete
Email

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Nikon NSR-2205i11D Step-and-Repeat System is a state-of-the-art workhorse for 0.35 micron lithography. The Nikon NSR-2205i11D is a step-and-repeat system.[1]

NSR-2205i11D — chiphistory.org
Fig. 01NSR-2205i11Dchiphistory.org[1]

Produced

1995–

Node / era

0.35 micron

Optics

0.35 micron[1]

What it is

The Nikon NSR-2205i11D is a step-and-repeat system. The Nikon NSR-2205i11D is an i-line stepper. The Nikon NSR-2205i11D has resolution of 350 nm or finer. The Nikon NSR-2205i11D uses an i-line exposure source at 365 nm. The Nikon NSR-2205i11D has numerical aperture of 0.63. The Nikon NSR-2205i11D uses 1:5 reduction projection. The Nikon NSR-2205i11D has a maximum exposure field of 22 mm × 22 mm. The Nikon NSR-2205i11D has overlay accuracy of 70 nm or better for EGA, |M| + 3σ. The Nikon NSR-2205i11D supports LSA as standard and FIA and LIA as optional alignment systems.[7][1]

How it works

General reference — not yet source-verified

A step-and-repeat lithography system projects a reduced image from a photomask onto photoresist on a wafer, exposes one field, then moves the wafer and repeats the exposure across the substrate. A machine in this class combines illumination optics, reticle handling, projection optics, wafer staging, focus control, and alignment sensing so that each patterned layer is placed in registration to earlier layers. An i-line stepper uses mercury-lamp spectral output in the i-line band to print features defined by the reticle pattern.

Where it fits in the process flow

General reference — not yet source-verified

Lithography steppers are used in wafer patterning after photoresist coating and before development and pattern transfer. A tool in this class defines lateral features for later etch, implant, deposition, or lift-off sequence steps. Overlay capability in this class is important because repeated lithography levels must register to structures formed earlier in the process flow.

Applications

General reference — not yet source-verified

I-line steppers are used for semiconductor wafer patterning on process layers that can be printed with mature optical lithography. Step-and-repeat exposure tools in this class are applied to repeated die imaging across the wafer and to layer-to-layer registration during integrated-circuit fabrication. Such tools are also used where reduction projection exposure is preferred over full-wafer contact or proximity printing.

What do the numbers mean?

Wafer handling1

Wafer size
8 Inch[2]
Accurate?

Optics & imaging9

Resolution node
0.35 micron[1]
Accurate?
Node (resolution)
0.35 micron[1]
Accurate?
Resolution
0.35 micron[1]
Accurate?
Resolution
0.35 µm[1]
Accurate?
Resolution
≤ 350 nm[7]
Accurate?
Exposure source
i-line (365 nm wavelength)[7]
Accurate?
Maximum exposure field
22 mm × 22 mm[7]
Accurate?
Overlay accuracy
≤ 70 nm (EGA, |M| + 3σ)[7]
Accurate?
Reticle size
6 Inch[2]
Accurate?

Performance1

Alignment system
LSA (standard), FIA (optional), LIA (optional)[7]
Accurate?

Configuration & options30

Tool type
Step-and-Repeat System[1]
Accurate?
Process node
0.35 micron[1]
Accurate?
Node
0.35 micron[1]
Accurate?
Technology Node
0.35 micron[1]
Accurate?
Type
Step-and-repeat system[1]
Accurate?
Process node
0.35 µm[1]
Accurate?
Machine type
Step-and-Repeat System[1]
Accurate?
Target design node
0.35 micron[1]
Accurate?
Type
Step-and-repeat system (stepper)[1]
Accurate?
System type
Step-and-repeat system[1]
Accurate?
Target node
0.35 micron[1]
Accurate?
System type
Step-and-repeat (stepper) lithography system[1]
Accurate?
Design node
0.35 micron[1]
Accurate?
Minimum feature size
0.35 μm[1]
Accurate?
Minimum feature size
0.35 micron[1]
Accurate?
Design Rule
0.35 micron[1]
Accurate?
Feature Size
0.35 micron[1]
Accurate?
Description
State-of-the-art workhorse[1]
Accurate?
Equipment type
Step-and-repeat system[1]
Accurate?
Node
0.35 µm[1]
Accurate?
Manufacturer
Nikon[1]
Accurate?
OEM
Nikon[1]
Accurate?
Model
NSR-2205i11D[1]2 sources
Accurate?
Model
NSR-2205i11D Step-and-Repeat System[1]
Accurate?
Described use
Step-and-Repeat System[1]
Accurate?
Tool type
i-line stepper[7]
Accurate?
NA
0.63[7]
Accurate?
Reduction ratio
1:5[7]
Accurate?
Date of manufacture
01 Sep 1995[2]
Accurate?
Serial number
1105183[2]
Accurate?

Vintage & configurations

  1. 1995-09-01Production start[2]

    A unit is dated 01 Sep 1995 as the date of manufacture.

Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

Alternatives

Tools documented as functional equivalents — same process step and wafer size, from a different manufacturer. Each equivalence cites its source.

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What kind of lithography tool is the NSR-2205i11D?

The Nikon NSR-2205i11D is a step-and-repeat system and an i-line stepper.[1][7]

What exposure wavelength does the NSR-2205i11D use?

The Nikon NSR-2205i11D uses i-line exposure at 365 nm.[7]

Not publicly documented

The following facts about the NSR-2205i11D are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the NSR-2205i11D are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the NSR-2205i11D are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the NSR-2205i11D are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • No publicly documented compatible parts, consumables, or accessories for the NSR-2205i11D are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the NSR-2205i11D are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (7)Every fact above is drawn from these public sources
  1. [1]chiphistory.org — chiphistory.orgchiphistory.org
  2. [2]nteklitho.com — nteklitho.comnteklitho.com
  3. [3]Inventory photo
  4. [4]Inventory photo
  5. [5]Inventory photo
  6. [6]Inventory photo
  7. [7]jp.nikon.com — jp.nikon.comjp.nikon.com
Was this page accurate?