Waferpedia

GCA

3696

150mmlegacy semiconductor lithography equipmentg-lineGCA 3696 family
Research Quality: 40% complete

The GCA 3696 is a step-and-repeat camera (or stepper) built around the DEC PDP-11/04 minicomputer using a 9280 Interface Chassis. The GCA 3696 was one of the first step-and-repeat cameras (or steppers) made by Mann/GCA. The GCA 3696 can be easily converted to function as a GCA 3696 Photorepeater system for exposing photoresist coated glass plates up to 7 inches.[1][2]

GCA3696
No photo available yet

Wafer size

150mm

Node / era

legacy semiconductor lithography equipment

Performance

Typically <0.25µm[2]

Gas delivery

Photoresist-coated glass plates[2]

Optics

g-line (436nm)[2]

What it is

The GCA 3696 is a step-and-repeat camera, also known as a photorepeater, manufactured by Mann/GCA. The GCA 3696 was one of the first such systems produced. The instrument can be configured to expose photoresist-coated glass plates for photomask fabrication.[2][1]

How it works

The GCA 3696 projects an image of a reticle onto a photoresist-coated glass plate and steps the plate to expose an array of identical die patterns. The system is built around a Digital Equipment Corporation PDP-11/04 minicomputer and uses a 9280 Interface Chassis. Operator control is via a VT100 console terminal, and data storage is on 8-inch floppy disk drives. When configured as a photorepeater, the system accommodates glass plates up to 7 inches in size.[1][2]

What can it run?

Process applications and technology nodes documented for this tool.

  • Photolithography
  • Exposing photoresist-coated glass plates

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • Back of substrate must be clean with no resist on back
  • Mask must be clean with no resist or fingerprints
  • Transparent/Opaque switch must be used in proper mode for substrates such as >2um SiO2 or glass

What do the numbers mean?

Wafer handling2

Wafer size
3" up to 150mm; smaller pieces[2]
Accurate?
Wafer size
150mm (6")[2]
Accurate?

Gas & chemistry1

Exposure target
Photoresist-coated glass plates[2]
Accurate?

Optics & imaging7

Exposure wavelength
g-line (436nm)[2]
Accurate?
Numerical aperture
0.30 N.A.[2]
Accurate?
Mask size
5" x 0.090"-thick masks[2]
Accurate?
Stage motion
Laser-controlled stage motion[2]
Accurate?
Type
Step-and-repeat camera (stepper)[1]
Accurate?
Lens
Zeiss lens with 0.30 numerical aperture[2]
Accurate?
Resolution
0.9 µm[2]
Accurate?

Performance1

Registered alignment
Typically <0.25µm[2]
Accurate?

Control & software2

Control computer
DEC PDP-11/04[1]
Accurate?
Interface chassis
9280 Interface Chassis[1]
Accurate?

Configuration & options8

Instrument type
Photorepeater system[2]
Accurate?
Conversion note
Can be easily converted to function as a GCA 3696 Photorepeater system[2]
Accurate?
Maximum plate size
Up to 7"[2]
Accurate?
Reduction
5:1 reduction[2]
Accurate?
Field size
Variable field size up to 15mm square[2]
Accurate?
Minimum feature size
<0.9µm[2]
Accurate?
Field size
15mm[2]
Accurate?
Reduction ratio
5:1[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
GCA 6300 DSW 5X g-line Wafer Stepperg-lineDescribed as a wafer stepper that can be converted to function as a GCA 3696 Photorepeater system.cnfusers.cornell.edu[2]
Interested in this tool?
Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Exposure targetPhotoresist-coated glass plates[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Frequently asked questions

What type of equipment is the GCA 3696?

The GCA 3696 is a step-and-repeat camera (photorepeater) made by Mann/GCA, one of the first of its kind.[1]

What is the maximum plate size the GCA 3696 can expose when configured as a photorepeater?

The system can expose photoresist-coated glass plates up to 7 inches in size.[2]

What interface chassis is used in the GCA 3696?

The system uses a 9280 Interface Chassis.[1]

What type of console terminal and storage does the GCA 3696 employ?

Operator interaction is through a VT100 console terminal, and data storage is on 8-inch floppy disk drives.[1]

Not publicly documented

The following facts about the 3696 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 3696 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 3696 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented compatible parts, consumables, or accessories for the 3696 are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the 3696 are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]trilicium.catrilicium.catrilicium.ca
  2. [2]cnfusers.cornell.educnfusers.cornell.educnfusers.cornell.edu
Was this page accurate?

Last updated Aug 13, 2026.

Compare with similar tools