Email

The Plasma-Therm SLR-770 is a shuttle-lock ICP etch system for chlorine etching. The Plasma-Therm SLR-770 has a vacuum load lock with a wafer transfer robot. The Plasma-Therm SLR-770 can process wafers from 2 inches to 8 inches depending on the installed process kit.[1][2]

Plasma-ThermSLR-770
No photo available yet
  • Plate 01Plasma-Therm SLR770 ICP Etcher Demonstration - System Overview - Part 1

    Gregory WrightWatch on YouTube
  • Plate 02Plasma-Therm SLR770 ICP Etcher Demonstration - Part 1

    Gregory WrightWatch on YouTube
  • Plate 03Plasma-Therm SLR770 ICP Etcher Demonstration - Part 2

    Gregory WrightWatch on YouTube
  • Plate 04Plasma-Therm SLR770 ICP Etcher Demonstration - Automatic Process Run

    Gregory WrightWatch on YouTube
  • Plate 05Plasma-Therm SLR770 ICP Etcher Demonstration - Part 3

    Gregory WrightWatch on YouTube
  • Plate 06Plasmatherm SLR-770 DRIE Bosch Process

    ClassOneVideosWatch on YouTube

Wafer size

2"

Vacuum

Vacuum load lock with wafer transfer robot[1]

Gas delivery

Total of eight MFC gas controllers[1]

What it is

General reference — not yet source-verified

Plasma etchers remove material from a wafer surface by exposing it to a low-pressure reactive discharge. ICP etchers are generally used when a process needs strong control of ion and radical generation for anisotropic or selective dry etching in microfabrication.

How it works

The Plasma-Therm SLR-770 uses a high-frequency RF-based inductively coupled plasma source capable of high-density plasma generation. The Plasma-Therm SLR-770 has closed-loop pressure control, a turbo pump with a roughing pump, and a thermal transfer module for substrate cooling that uses helium backside thermal transfer together with computer-controlled substrate clamping. The Plasma-Therm SLR-770 has a total of eight mass flow controller gas channels and includes a water chiller.[1]

Where it fits in the process flow

General reference — not yet source-verified

Plasma etchers are used after pattern definition when a masking layer has already been formed on the wafer. Plasma etchers transfer that pattern into underlying films or substrates, and later process steps commonly include mask stripping, cleaning, metrology, deposition, or additional lithography depending on the device flow.

What can it run?

Process applications and technology nodes documented for this tool.

  • Chlorine etching

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • One source states that the tool is currently configured with a 3-inch kit while another source lists the wafer size as 2 inches.

What do the numbers mean?

Power & electrical1

Plasma source
High frequency RF-based inductively coupled plasma source capable of high density plasma generation[1]
Accurate?

Vacuum & pumping3

Load lock
Vacuum load lock with wafer transfer robot[1]
Accurate?
Pressure control
Closed loop pressure control[1]
Accurate?
Pumping
Turbo pump with roughing pump[1]
Accurate?

Wafer handling4

Wafer size capability
Can process wafers from 2" to 8" depending on which process kit is installed[1]
Accurate?
Thermal transfer
Thermal transfer module for effective cooling of substrate utilizing helium backside thermal transfer in conjunction with computer controlled substrate clamping[1]
Accurate?
Wafer size capability
2" to 8" depending on which process kit is installed[1]
Accurate?
Wafer size
2"[2]
Accurate?

Gas & chemistry3

Gas controllers
Total of eight MFC gas controllers[1]
Accurate?
Previously used gases
N2, O2, CHF3, AR, CH4, CL2, BCL3, CF4[1]
Accurate?
Listed gases
N2, O2, CHF3, Ar, CH4, Cl2, BCl3, CF4[1]
Accurate?

Control & software1

Controller
PC controller[1]
Accurate?

Configuration & options5

System type
Shuttle lock ICP inductively coupled plasma etch system[1]
Accurate?
Current configuration
Currently configured with 3" kit[1]
Accurate?
Included accessory
Water chiller[1]
Accurate?
Etch application
Chlorine etching[1]
Accurate?
Current configuration
3" kit[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Load lockVacuum load lock with wafer transfer robot[1]
  • Plasma sourceHigh frequency RF-based inductively coupled plasma source capable of high density plasma generation[1]
  • Pressure controlClosed loop pressure control[1]
  • PumpingTurbo pump with roughing pump[1]
  • Gas controllersTotal of eight MFC gas controllers[1]
  • Previously used gasesN2, O2, CHF3, AR, CH4, CL2, BCL3, CF4[1]
  • Listed gasesN2, O2, CHF3, Ar, CH4, Cl2, BCl3, CF4[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

Does the Plasma-Therm SLR-770 have a load lock and wafer transfer robot?

The Plasma-Therm SLR-770 has a vacuum load lock with a wafer transfer robot.[1]

Not publicly documented

The following facts about the SLR-770 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the SLR-770 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the SLR-770 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the SLR-770 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the SLR-770 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the SLR-770 are on record.

    Answerable by: an OEM parts catalog or a service engineer

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]nanolab.ucla.edu — nanolab.ucla.edunanolab.ucla.edu
  2. [2]waferpedia.com — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 19, 2026.

Compare with similar tools

View all →