The Chroma 80611 Timing/Noise Analyzer is a module specially designed to enhance the test capability of the Chroma POWER PRO III Power Supply ATS system. The Chroma 80611 provides up to 10 channels for VDC input to measure timing and noise, and includes 8 pairs of built-in relays and 16 bits of TTL control signals for user-defined control applications. The Chroma 80611 can be populated with up to ten 80611N noise cards for parallel and differential noise readings.[1][2]

Chroma80611
No photo available yet

Power

115 VAC / 230 VAC (±10%), 60 Hz / 50 Hz[2]

Optics

15 bits[2]

What it is

The Chroma 80611 is a timing and noise analyzer module designed for use in Chroma's automated test systems (ATS) for power supply testing. The 80611 can be populated with up to ten noise cards, each with a 20 MHz bandwidth. The module provides ten channels for DC voltage input to measure timing and noise parameters.[3][2][1]

The Chroma 80611 provides auxiliary controls including eight pairs of built-in relays and 16-bit TTL input/output signals. The module includes six external trigger sources that create a total of 24 different triggering options. For high-bandwidth applications the 80611 can be configured with up to two 10-input by 2-output, 100 MHz high-frequency multiplexer cards to route signals to an oscilloscope.[2][4]

How it works

The Chroma 80611 Timing and Noise Analyzer is a module that installs into a Chroma C8000 or Power Pro III automated test system. The module is controlled exclusively by the Chroma ATS test program through a GPIB bus; there is no keypad or general GPIB command control. The 80611 accepts up to ten DC voltage input channels routed through user-selectable multiplexers that can also pass signals to an external digital voltmeter or oscilloscope.[2][1]

Each noise card installed in the 80611 provides parallel and differential measurements of voltage parameters including peak-to-peak, RMS, overshoot, undershoot, turn-on time, turn-off time, rise time, and fall time. The 80611N noise card has a bandwidth of up to 400 kHz for dynamic voltage peak measurements and a noise specification bandwidth of 6 Hz to 20 MHz. The mainframe provides a 10 x 4 low-frequency multiplexer for routing signals to the system DMM or scope.[2]

Applications

The Chroma 80611 is applied in automated test systems for high-speed switching power supply testing. The module is suited for testing multiple-output power supplies by providing parallel timing and noise measurements. The 80611 is also used in systems designed for testing LED power drivers, adapters, and battery chargers.[2][1]

What do the numbers mean?

Power & electrical5

Power Requirement Voltage
115 VAC / 230 VAC (±10%), 60 Hz / 50 Hz[2]
Accurate?
Max Input Voltage
30 VDC[2]
Accurate?
Relay Voltage Rating (Floating Relays)
0~220 VDC, 0~250 VAC[2]
Accurate?
Noise Card Input Voltage Range
6 V / 30 V / 120 V / 500 V[2]
Accurate?
Noise Card Bandwidth
400 kHz[2]
Accurate?

Optics & imaging1

Noise Card Resolution
15 bits[2]
Accurate?

Dimensions & facilities2

Weight
25 kg (55 lbs)[2]
Accurate?
Dimensions (H x W x D)
177 mm x 423 mm x 563 mm (7" x 16.88" x 22")[2]
Accurate?

Configuration & options6

Power Requirement Current
1.5 A for 110 VAC, 0.75 A for 230 VAC[2]
Accurate?
Number of TTL Input Channels
16 bits, standard TTL[2]
Accurate?
Number of TTL Output Channels
16 bits, standard TTL[2]
Accurate?
Number of Floating Relays
8 pairs[2]
Accurate?
Relay Life (Floating Relays)
50,000 cycles at 1800 operations/hour with rated load[2]
Accurate?
Relay Current Rating (Floating Relays)
0~2 A[2]
Accurate?
Interested in this tool?
Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power Requirement Voltage115 VAC / 230 VAC (±10%), 60 Hz / 50 Hz[2]
  • Max Input Voltage30 VDC[2]
  • Relay Voltage Rating (Floating Relays)0~220 VDC, 0~250 VAC[2]
  • Noise Card Input Voltage Range6 V / 30 V / 120 V / 500 V[2]
  • Noise Card Bandwidth400 kHz[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Not publicly documented

The following facts about the 80611 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 80611 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 80611 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 80611 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 80611 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 80611 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]80611 Timing/Noise Analyzer User’s Manualen.sekorm.comen.sekorm.com
  2. [2]chromausa.comchromausa.comchromausa.com
  3. [3]Equipment inventory listing
  4. [4]Chroma 80611 Timing & Noise Analyzer (Used), Chroma, 80611, Timing & Noise Analyzer - China (mainland) Chroma, 80611, Used in Analyzers/n.e.s. on ttnet.netttnet.netttnet.net
Was this page accurate?

Last updated Aug 24, 2026.

Compare with similar tools

View all →