Waferpedia

Nutek

NTM 650 SXXL Multifunction Vertical Buffer

Assembly / SMTNutek NTM family
Research Quality: 50% complete
Email

The Nutek NTM 650 SXXL Multifunction Vertical Buffer is a vertical buffer. The Nutek NTM 650 SXXL Multifunction Vertical Buffer uses XXL size Open LIFO operation. The Nutek NTM 650 SXXL Multifunction Vertical Buffer supports three modes: Standard, Reject, and Bypass.[1][2]

NTM 650 SXXL Multifunction Vertical Buffer — Inventory photo
Fig. 01NTM 650 SXXL Multifunction Vertical BufferInventory photo[1]

Power

220V, 50/60Hz[1]

Vacuum

4-6 Bar[1]

What it is

The Nutek NTM 650 SXXL Multifunction Vertical Buffer is a vertical buffer with XXL size and Open LIFO operation. The machine has three modes named Standard, Reject, and Bypass.[1][2]

The NTM 650 SXXL is a PCB-handling buffer with a left-to-right transfer direction. The machine is specified for a transfer height of 900 mm with a tolerance of plus or minus 25 mm.[1][2]

How it works

The machine operates on 220V power at 50/60Hz and uses pressure from 4-6 Bar with air consumption of 2 L/min. The machine allows component height of 30 mm max above and 30 mm max below.[1][2]

Applications

The NTM 650 SXXL is specified for PCB sizes from 50 mm to 535 mm in width and 80 mm to 850 mm in length. The product thickness range is 0.60 mm to 1.60 mm.[1][2]

What do the numbers mean?

Power & electrical1

Voltage
220V, 50/60Hz[1]
Accurate?

Vacuum & pumping1

Pressure
4-6 Bar[1]
Accurate?

Wafer handling1

Transfer height
900mm (+/-25mm)[1]
Accurate?

Dimensions & facilities3

Component Height
Top: 30mm max/ Below: 30mm max[1]
Accurate?
Component height above
30mm max[1]
Accurate?
Component height below
30mm max[1]
Accurate?

Configuration & options15

XXL size[1]
Accurate?
Open LIFO[1]
Accurate?
Phase
1 Phase[1]
Accurate?
Direction
Left to Right[1]
Accurate?
PCB size
50 – 535mm (W)/ 80 -850mm (L)[1]
Accurate?
Product thickness
0.60 – 1.60mm[1]
Accurate?
Air consumption
2 L/min[1]
Accurate?
3 modes
Standard, Reject, Bypass[1]
Accurate?
OEM
Nutek[1]
Accurate?
Model
NTM 650 SXXL[1]
Accurate?
Type
Multifunction Vertical Buffer[1]
Accurate?
Size
XXL size[2]
Accurate?
Operation
Open LIFO[2]
Accurate?
Modes
Standard, Reject, Bypass[1]
Accurate?
Vintage
2013[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage220V, 50/60Hz[1]
  • Pressure4-6 Bar[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What operating modes does the Nutek NTM 650 SXXL support?

The Nutek NTM 650 SXXL supports three modes: Standard, Reject, and Bypass.[1][2]

What transfer direction does the Nutek NTM 650 SXXL use?

The Nutek NTM 650 SXXL uses a left-to-right transfer direction.[1][2]

Not publicly documented

The following facts about the NTM 650 SXXL Multifunction Vertical Buffer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the NTM 650 SXXL Multifunction Vertical Buffer are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the NTM 650 SXXL Multifunction Vertical Buffer are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the NTM 650 SXXL Multifunction Vertical Buffer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the NTM 650 SXXL Multifunction Vertical Buffer are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the NTM 650 SXXL Multifunction Vertical Buffer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]waferpedia.com — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 19, 2026.

Compare with similar tools